PAUSE 500
DEBUG CR,"!RSET",CR,
DEBUG "@TEXT 1A,D0,1A,(Blue), Start Sw",CR,
DEBUG "!O lblData = Mix Time:\n(Sec)",CR,
DEBUG "!O Meter = 0,0,500",CR
DEBUG "!RSET",CR
' -----[ Main Routine ]----------------------------------------------------
DO
DO UNTIL (Start_Sw = 0)
LOOP
DEBUG "!READ (txtData)",CR
DEBUGIN DEC Mix_Seconds
HIGH Fill
DEBUG "!O Stat1 = Filling",CR
DO UNTIL (Opto_Sw = 0)
LOOP
LOW Fill
HIGH Mix
FOR X = 1 TO Mix_Seconds
GOSUB Display_Data
GOSUB Display_Data
GOSUB Display_Data
"!CLRC",CR,
"!SPAN 0,500",CR
"@TEXT 1A,D1,1A,(Blue), Proximity Detector",CR,
"@TEXT 1A,D2,1A,(Blue), Stop Sw",CR,
"@TEXT 1A,D3,1A,(Blue), Fill",CR,
"@TEXT 1A,D4,1A,(Blue), Mix",CR,
"@TEXT 1A,D5,1A,(Blue), Drain",CR
"!O txtData = 15",CR,
"!O txtR = Filling",CR,
"!O txtY = Mixing",CR,
"!O txtG = Draining",CR,
"!O Stat1 = Idle",CR,
"!O Stat2 = Total Gallons:",CR,
"!O txtFileName = Mix_Seq",CR
DEBUG "!O Stat1 = Mixing ",
PAUSE 900
DEC X,
" Seconds", CR
' Connection stabilizing time
' Reset StampPlot
' Clear any text on plot
' Set Y-Axis span
' Set SP meter - current,min val, max val
' Reset after configuring
' Wait until start button pressed
' Read time to mix from plot
' Accept data, store in Mix_Seconds.
' Begin fill
' Wait until stop button is pressed
' Stop fill
' Start mixing
' Mix while updating plot
' 100 pause in Display Data added to this
' Label digital data traces
' Label input text box area
' Set initial value for mix time
' Label other controls
' Label file name for saves