NS5-MQ10B-V2 Omron, NS5-MQ10B-V2 Datasheet - Page 157

no-image

NS5-MQ10B-V2

Manufacturer Part Number
NS5-MQ10B-V2
Description
5 Mono Tchsrn,Serial+USB,Bk 60
Manufacturer
Omron
Datasheet

Specifications of NS5-MQ10B-V2

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Set the upper digit using the top rotary switch and the lower digit using the bottom rotary
switch.
The factory setting is 01.
When using automatic generation to convert addresses, set the node number to the same
value as that of the rightmost byte of the local IP address. If the same values cannot be set,
the IP address table method or combination method must be used to convert the addresses.
Setting Local IP Addresses
For CJ-series Ethernet Units, set the local IP address from the CX-Programmer or other
Support Software for the CPU Unit. Refer to the SYSMAC CS/CJ Series Ethernet Unit Op-
eration Manual (Cat. No. W343) for details on setting methods.
Ethernet Connectors
This is the connector used to connect the twisted-pair cable to the Ethernet.
• Electrical Characteristics: Conforms to IEEE802.3 standards.
• Connector Layout: RJ45 8-pin modular connector (conforms to ISO8877).
EtherNet/IP Unit for CJ-series PLCs:
Setting the Front Panel Switches
Setting Unit Numbers
Always set the unit numbers so that the unit numbers of other CPU Bus Units mounted to the
same CPU Unit are all unique.
Use a small screwdriver to set the rotary switches, being careful not to damage them.
The factory setting is 0.
Setting Node Numbers
Set the node numbers as hexadecimal values with the node number setting switch. Always
set the node numbers so that other Ethernet Units connected to the same Ethernet network
all have unique addresses. As long as the addresses are unique, they can be set between 01
CJ1W-ETN11
CS1W-ETN21
CJ1W-EIP21
1
8
1
2
3
4
5
6
7
8
Connec-
tor Pin
Setting range
Send data
Send data −
Receive data +
Not used.
Not used.
Receive data −
Not used.
Not used.
0 to F
Signal name
TD−
RD−
TD+
RD+
Abbreviation
5-1 Connecting to Host Via Ethernet
Output
Output
Input
Input
Signal direction
5-13

Related parts for NS5-MQ10B-V2