NS5-MQ10B-V2 Omron, NS5-MQ10B-V2 Datasheet - Page 71

no-image

NS5-MQ10B-V2

Manufacturer Part Number
NS5-MQ10B-V2
Description
5 Mono Tchsrn,Serial+USB,Bk 60
Manufacturer
Omron
Datasheet

Specifications of NS5-MQ10B-V2

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
3-4-2
Setting Bar Code Readers
The Bar Code Reader’s communications conditions and other settings can be set from either
the CX-Designer or the PT.
Use the CX-Designer to set PT settings, such as the conditions for communications with the
Bar Code Reader, according to the following table. Set the communications conditions sup-
ported by the Bar Code Reader to suit the application environment.
Set the communications conditions from the System Menu.
For details on specific methods for operating the System Menu, refer to 6-6-6 Setting Bar
Code Readers.
Set the settings for the Bar Code Reader according to the following table. Make sure, how-
ever, that the communications conditions settings for the communications speed, parity, stop
bits, and data bits, match those set for the PT. For details on setting methods, refer to the
operation manual of the Bar Code Reader being used.
Data bits
Stop bits
Parity
Communications
Speed
Input method
Communications Speed
Parity
Stop bits
Data bits
Preamble
Postamble
RS/CS control
Communications protocol
Bar code label digit transfer
ID character transfer
Bar code types
Trigger switch setting
Setting from the CX-Designer
Setting from the PT
Bar Code Reader Settings
Item
Item
7 or 8 bits
1 or 2 bits
None, odd, or even
4,800, 9,600, or 19,200 bps
Manual or Auto
4,800, 9,600, or 19,200 bps
Even, odd, or none.
1 or 2 bits
7 or 8 bits
STX
ETX
Invalid
No protocol mode
Transfer prohibited.
Transfer prohibited.
Multi-read (reads everything)
Automatic read mode
Settings
Settings
7 bits
2 bits
Even
9,600 bps
Auto
3-4 Connecting to Bar Code Readers
Default
3-17