NS5-MQ10B-V2 Omron, NS5-MQ10B-V2 Datasheet - Page 162

no-image

NS5-MQ10B-V2

Manufacturer Part Number
NS5-MQ10B-V2
Description
5 Mono Tchsrn,Serial+USB,Bk 60
Manufacturer
Omron
Datasheet

Specifications of NS5-MQ10B-V2

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
5-2 Connecting to the Host Using Controller Link
5-2-2
5-18
Data Links
What Are Data Links?
Note: For details on the CPU Units that support connection to Controller Link Units, refer to Appendix 8
This section outlines data links and the method of setting data link tables when using data
links. For details, refer to the Controller Link Support Board Operation Manual (W307), Con-
troller Link Unit Operation Manual (Cat. No. W309), and the Controller Link Support Board for
PCI Bus Operation Manual (Cat. No. W383).
Data links automatically exchange preset data between nodes (i.e., between PLCs, between
a PLC and an IBM PC/AT or compatible computer, or between a PLC and an NS-series PT).
Data links can be freely created for CS-series PLCs, C200HX/HG/HE PLCs, CVM1, CV-
series PLCs, CJ-series PLCs, CQM1H-series PLCs, and NS-series PTs.
Two data link areas, area 1 and area 2, can be set for each node. Data links can be set in ei-
ther of the following ways.
• Data link areas can be set by inputting data link tables through the Controller Link Support
• Data links can be set automatically from a Programming Device. With automatically set
Automatic setting and manual setting cannot be used together in the same network.
The following rules apply to these methods of setting data links.
1. Data links are enables concurrently for area 1 and area 2.
2. Separate settings (data link start words and send area size) are made in area 1 and area
3. Not all nodes must participate in the data links.
Controller Link Unit
(See note.)
Controller Link Sup-
port Board (ISA
Bus/PC98)
Controller Link Sup-
port Board (PCI Bus)
Twisted-pair Cable
Controller Link Wired
Relay Terminal Block
Software. Data link tables are created to define the data links. These tables enable free al-
location of data link areas.
data links, all link areas are the same size.
2. The sequences of send and receive words are the same in area 1 and area 2.
Standard Models.
Device
CVM1-CLK21
C200HW-CLK21
CS1W-CLK21
CQM1H-CLK21
CJ1W-CLK21
3G8F5-CLK21
3G8F6-CLK21
3G8F7-CLK21
ESVC0.5×2C
CJ1W-TB101
Model
Required to connect PLC with
Controller Link Network.
Required to connect IBM
PC/AT or compatible com-
puters with Controller Link
Network.
Required to connect the PT,
PLC, and IBM PC/AT or com-
patible computers. Use
shielded twisted-pair cable.
Used as a relay terminal block
for wires and can be used as
required to facilitate replace-
ment and maintenance of Con-
troller Link Units and Boards
after the communications sys-
tem has been started.
Remarks

Related parts for NS5-MQ10B-V2