DS26324 3.3V, 16-Channel, E1/T1/J1 Short-Haul Line Interface Unit
7.1 TAP Controller State Machine
The TAP controller is a finite state machine that responds to the logic level at TMS on the rising edge of TCLK. The
state diagram is shown in
Figure 7-2.
7.1.1 Test-Logic-Reset
Upon power-up, the TAP controller will be in the Test-Logic-Reset state. The instruction register will contain the
IDCODE instruction. All system logic of the device will operate normally. This state is automatically entered during
power-up. This state is entered from any state if the TMS is held high for at least 5 clocks.
7.1.2 Run-Test-Idle
The Run-Test-Idle is used between scan operations or during specific tests. The instruction register and test
registers will remain idle. The controller remains in this state when TMS is held low. When the TMS is high and
rising edge of TCLK is applied the controller moves to the Select-DR-Scan state.
7.1.3 Select-DR-Scan
All test registers retain their previous state. With TMS LOW, a rising edge of TCLK moves the controller into the
Capture-DR state and will initiate a scan sequence. TMS HIGH during a rising edge on TCLK moves the controller
to the Select-IR-Scan state.
7.1.4 Capture-DR
Data can be parallel-loaded into the test-data registers if the current instruction is EXTEST or SAMPLE/PRELOAD.
If the instruction does not call for a parallel load or the selected register does not allow parallel loads, the test
register will remain at its current value. On the rising edge of TCLK, the controller will go to the shift-DR state if
TMS is LOW or it will go to the exit1-DR state if TMS is HIGH.
7.1.5 Shift-DR
The test-data register selected by the current instruction will be connected between TDI and TDO and will shift data
one stage towards its serial output on each rising edge of TCLK. If a test register selected by the current instruction
is not placed in the serial path, it will maintain its previous state. When the TAP controller is in this state and a
rising edge of TCLK is applied, the controller enters the Exit1-DR state if TMS is high or remains in Shift-DR state if
TMS is low.
7.1.6 Exit1-DR
While in this state, a rising edge on TCLK will put the controller in the Update-DR state, which terminates the
scanning process, if TMS is HIGH. A rising edge on TCLK with TMS LOW will put the controller in the Pause-DR
state.
7.1.7 Pause-DR
Shifting of the test registers is halted while in this state. All test registers selected by the current instruction will
retain their previous state. The controller will remain in this state while TMS is LOW. A rising edge on TCLK with
TMS HIGH will put the controller in the Exit2-DR state.
7.1.8 Exit2-DR
A rising edge on TCLK with TMS HIGH while in this state will put the controller in the Update-DR state and
terminate the scanning process. A rising edge on TCLK with TMS LOW will enter the Shift-DR state.
7.1.9 Update-DR
A falling edge on TCLK while in the Update-DR state will latch the data from the shift register path of the test
registers into the data output latches. This prevents changes at the parallel output due to changes in the shift
register.