mg84fl54 Megawin Technology, mg84fl54 Datasheet - Page 45

no-image

mg84fl54

Manufacturer Part Number
mg84fl54
Description
Full-speed Usb Micro-controller
Manufacturer
Megawin Technology
Datasheet
In the 9 bit UART modes, mode 2 and mode 3, the Receive Interrupt flag (RI) will be automatically set when the
received byte contains either the “Given” address or the “Broadcast” address. The 9-bit mode requires that the
9th information bit is a 1 to indicate that the received information is an address and not data. Automatic address
recognition is shown in Fig 12-9. The 8 bit mode is called Mode 1. In this mode the RI flag will be set if SM2 is
enabled and the information received has a valid stop bit following the 8 address bits and the information is
either a Given or Broadcast address. Mode 0 is the Shift Register mode and SM2 is ignored.
Using the Automatic Address Recognition feature allows a master to selectively communicate with one or more
slaves by invoking the Given slave address or addresses. All of the slaves may be contacted by using the
Broadcast address. Two special Function Registers are used to define the slave’s address, SADDR, and the
address mask, SADEN.
SADEN is used to define which bits in the SADDR are to be used and which bits are “don’t care”. The SADEN
mask can be logically ANDed with the SADDR to create the “Given” address which the master will use for
addressing each of the slaves. Use of the Given address allows multiple slaves to be recognized while
excluding others.
The following examples will help to show the versatility of this scheme:
In the above example SADDR is the same and the SADEN data is used to differentiate between the two slaves.
Slave 0 requires a 0 in bit 0 and it ignores bit 1. Slave 1 requires a 0 in bit 1 and bit 0 is ignored. A unique
address for Slave 0 would be 1100 0010 since slave 1 requires a 0 in bit 1. A unique address for slave 1 would
be 1100 0001 since a 1 in bit 0 will exclude slave 0. Both slaves can be selected at the same time by an
address which has bit 0 = 0 (for slave 0) and bit 1 = 0 (for slave 1). Thus, both could be addressed with 1100
0000.
In a more complex system the following could be used to select slaves 1 and 2 while excluding slave 0:
In the above example the differentiation among the 3 slaves is in the lower 3 address bits. Slave 0 requires that
bit 0 = 0 and it can be uniquely addressed by 1110 0110. Slave 1 requires that bit 1 = 0 and it can be uniquely
addressed by 1110 0101. Slave 2 requires that bit 2 = 0 and its unique address is 1110 0011. To select Slaves
0 and 1 and exclude Slave 2 use address 1110 0100, since it is necessary to make bit 2 = 1 to exclude slave 2.
The Broadcast Address for each slave is created by taking the logical OR of SADDR and SADEN. Zeros in this
result are treated as don’t-cares. In most cases, interpreting the don’t-cares as ones, the broadcast address will
be FF hexadecimal.
Upon reset SADDR (SFR address 0A9H) and SADEN (SFR address 0B9H) are loaded with 0s. This produces a
given address of all “don’t cares” as well as a Broadcast address of all “don’t cares”. This effectively disables the
Automatic Addressing mode and allows the micro-controller to use standard 80C51 type UART drivers which do
not make use of this feature.
MEGAWIN
Slave 0
SADDR = 1100 0000
SADEN = 1111 1101
Given = 1100 00X0
Slave 0
SADDR = 1100 0000
SADEN = 1111 1001
Given = 1100 0XX0
Slave 1
SADDR = 1100 0000
SADEN = 1111 1110
Given = 1100 000X
Slave 1
SADDR = 1110 0000
SADEN = 1111 1010
Given = 1110 0X0X
MG84FL54B Data sheet
Slave 2
SADDR = 1110 0000
SADEN = 1111 1100
Given = 1110 00XX
45

Related parts for mg84fl54