HD64F2319VTE25 Renesas Electronics America, HD64F2319VTE25 Datasheet - Page 558

IC H8S MCU FLASH 512K 100-QFP

HD64F2319VTE25

Manufacturer Part Number
HD64F2319VTE25
Description
IC H8S MCU FLASH 512K 100-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of HD64F2319VTE25

Core Processor
H8S/2000
Core Size
16-Bit
Speed
25MHz
Connectivity
SCI, SmartCard
Peripherals
POR, PWM, WDT
Number Of I /o
71
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2319VTE25
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 13 Smart Card Interface
Data Transfer Operation by DTC: In smart card mode, as with the normal SCI, transfer can be
carried out using the DTC. In a transmit operation, the TDRE flag is also set to 1 at the same time
as the TEND flag in SSR, and a TXI interrupt is generated. If the TXI request is designated
beforehand as a DTC activation source, the DTC will be activated by the TXI request, and transfer
of the transmit data will be carried out. The TDRE and TEND flags are automatically cleared to 0
when data transfer is performed by the DTC. In the event of an error, the SCI retransmits the same
data automatically. Thus, the number of bytes specified by the SCI is transmitted automatically
even in retransmission following an error. However, the ERS flag is not cleared automatically
when an error occurs, and so the RIE bit should be set to 1 beforehand so that an ERI request will
be generated in the event of an error, and the ERS flag will be cleared.
When performing transfer using the DTC, it is essential to set and enable the DTC before carrying
out SCI setting. For details of the DTC setting procedures, see section 7, Data Transfer Controller.
In a receive operation, an RXI interrupt request is generated when the RDRF flag in SSR is set to
1. If the RXI request is designated beforehand as a DTC activation source, the DTC will be
activated by the RXI request, and transfer of the receive data will be carried out. The RDRF flag is
cleared to 0 automatically when data transfer is performed by the DTC. If an error occurs, an error
flag is set but the RDRF flag is not. Consequently, the DTC is not activated, but instead, an ERI
interrupt request is sent to the CPU. Therefore, the error flag should be cleared.
Note: For details of operation in block transfer mode, see section 12.4, SCI Interrupts.
Rev.7.00 Feb. 14, 2007 page 524 of 1108
REJ09B0089-0700

Related parts for HD64F2319VTE25