Specifications of S9S12HY64J0MLH

Core Processor
HCS12
Core Size
16-Bit
Speed
32MHz
Connectivity
CAN, EBI/EMI, I²C, IrDA, LIN, SCI, SPI
Peripherals
LCD, Motor control PWM, POR, PWM, WDT
Number Of I /o
50
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Eeprom Size
4K x 8
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 6x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
64-LQFP
Controller Family/series
S12
No. Of I/o's
50
Ram Memory Size
4KB
Cpu Speed
64MHz
No. Of Timers
2
Rohs Compliant
Yes
Processor Series
S12HY
Core
HCS12
3rd Party Development Tools
EWHCS12
Development Tools By Supplier
DEMO9S12HY64
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S9S12HY64J0MLH
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
9.3.2.10
The CANTAAK register indicates the successful abort of a queued message, if requested by the
appropriate bits in the CANTARQ register.
1. Read: Anytime
9.3.2.11
The CANTBSEL register allows the selection of the actual transmit message buffer, which then will be
accessible in the CANTXFG register space.
1. Read: Find the lowest ordered bit set to 1, all other bits will be read as 0
Freescale Semiconductor
Module Base + 0x0009
Module Base + 0x000A
ABTAK[2:0]
Write: Unimplemented
Write: Anytime when not in initialization mode
Field
2-0
Reset:
Reset:
W
W
R
R
Figure 9-13. MSCAN Transmitter Message Abort Acknowledge Register (CANTAAK)
Abort Acknowledge — This flag acknowledges that a message was aborted due to a pending abort request
from the CPU. After a particular message buffer is flagged empty, this flag can be used by the application
software to identify whether the message was aborted successfully or was sent anyway. The ABTAKx flag is
cleared whenever the corresponding TXE flag is cleared.
0 The message was not aborted.
1 The message was aborted.
MSCAN Transmitter Message Abort Acknowledge Register (CANTAAK)
MSCAN Transmit Buffer Selection Register (CANTBSEL)
The CANTAAK register is held in the reset state when the initialization
mode is active (INITRQ = 1 and INITAK = 1).
0
0
0
0
7
7
Figure 9-14. MSCAN Transmit Buffer Selection Register (CANTBSEL)
= Unimplemented
= Unimplemented
Table 9-16. CANTAAK Register Field Descriptions
6
0
0
6
0
0
MC9S12HY/HA-Family Reference Manual Rev. 1.04
0
0
0
0
5
5
NOTE
4
0
0
4
0
0
Description
Freescale’s Scalable Controller Area Network (S12MSCANV3)
0
0
0
0
3
3
ABTAK2
TX2
2
0
2
0
Access: User read/write
Access: User read/write
ABTAK1
TX1
0
0
1
1
ABTAK0
TX0
0
0
0
0