PCA9665PW,118 NXP Semiconductors, PCA9665PW,118 Datasheet - Page 44

IC CNTRLR PARALLEL/I2C 20TSSOP

PCA9665PW,118

Manufacturer Part Number
PCA9665PW,118
Description
IC CNTRLR PARALLEL/I2C 20TSSOP
Manufacturer
NXP Semiconductors
Datasheet

Specifications of PCA9665PW,118

Package / Case
20-TSSOP
Controller Type
I²C Bus Controller
Interface
I²C
Voltage - Supply
2.3 V ~ 3.6 V
Current - Supply
100µA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-4070-2
935279244118
PCA9665PW-T
PCA9665PW-T
Table 40.
Status
code
(I2CSTA)
E8h
A0h
Slave Receiver Buffered mode (MODE = 1)
Status of the
I
PCA9665
Previously addressed
with General Call;
BC[6:0] data bytes
have been received;
ACK has been
returned for all the
bytes, except for the
last one where NACK
bit has been returned
A STOP condition or
repeated START
condition has been
received while still
addressed as slave
receiver
2
C-bus and the
Application software response
To/from I2CDAT
Read data bytes
or
Read data bytes
or
Read data bytes
or
Read data bytes
No I2CDAT action
or
No I2CDAT action
or
No I2CDAT action
or
No I2CDAT action X
To/from I2CCOUNT
LB BC[6:0]
X
X
X
X
X
X
X
…continued
X
X
X
X
X
X
X
X
To I2CCON
STA STO SI
0
0
1
1
0
0
1
1
X
X
X
X
X
X
X
X
0
0
0
0
0
0
0
0
AA MODE
0
1
0
1
0
1
0
1
1
1
1
1
1
1
1
1
Next action taken by the PCA9665
Switched to not addressed slave mode;
No recognition of own slave address;
General Call address will be recognized if GC = 1
Switched to not addressed slave mode;
Own slave address will be recognized;
General Call address will be recognized if GC = 1
Switched to not addressed slave mode;
No recognition of own slave address;
General Call address will be recognized if GC = 1;
A START condition will be transmitted when the
bus becomes free.
Switched to not addressed slave mode;
Own slave address will be recognized;
General Call address will be recognized if GC = 1;
A START condition will be transmitted when the
bus becomes free.
Switched to not addressed slave mode;
No recognition of own slave address;
General Call address will be recognized if GC = 1
Switched to not addressed slave mode;
Own slave address will be recognized;
General Call address will be recognized if GC = 1
Switched to not addressed slave mode;
No recognition of own slave address;
General Call address will be recognized if GC = 1;
A START condition will be transmitted when the
bus becomes free.
Switched to not addressed slave mode;
Own slave address will be recognized;
General Call address will be recognized if GC = 1;
A START condition will be transmitted when the
bus becomes free.

Related parts for PCA9665PW,118