DS80C400 Maxim, DS80C400 Datasheet - Page 66

no-image

DS80C400

Manufacturer Part Number
DS80C400
Description
The DS80C400 network microcontroller offers the highest integration available in an 8051 device
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS80C400
Manufacturer:
DALLAS
Quantity:
748
Part Number:
DS80C400-FNY
Manufacturer:
DALLAS
Quantity:
85
Part Number:
DS80C400-FNY
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS80C400-FNY+
Manufacturer:
TDK-Lambda
Quantity:
34
Part Number:
DS80C400-FNY+
Manufacturer:
Maxim
Quantity:
3 861
Part Number:
DS80C400-FNY+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS80C400-FNY+
Manufacturer:
MAXI/DALLAS
Quantity:
20 000
NOCRS, No Carrier. This bit is only valid in half-duplex mode.
0 = transmit frame was not aborted due to lack of carrier
1 = transmit frame aborted due to lack of carrier (CRS = 0 when transmit frame initiated)
JABTO, Jabber Timeout
0 = transmit frame was not aborted due to jabber timeout
1 = transmit frame aborted due to jabber timeout (MAC transmitter has been active for twice the Ethernet max
frame length)
ABORT, Frame Aborted
0 = transmit frame was not aborted
1 = transmit frame was aborted by the MAC due to one of the following conditions: jabber timeout, no carrier, loss
of carrier, excessive deferral, late collision, retry count exceeds the attempt limit, and data underrun
Receive Status Word
Bit Names:
MF, Missed Frame
0 = receive frame was not missed
1 = receive frame missed
PF, Packet Filter
0 = current frame failed the packet filter
1 = current frame passed the packet filter
FF, Filter Fail
0 = destination address of the current receive frame passed the applied address filter
1 = destination address of the current receive frame failed the applied address filter
BCF, Broadcast Frame
0 = receive frame is not a broadcast frame
1 = receive frame is a broadcast frame (i.e., destination address is all ones)
MCF, Multicast Frame
0 = receive frame is not a multicast frame
1 = receive frame is a multicast frame (i.e., first bit of the destination address is a 1)
UCTRL, Unsupported Control Frame. This bit is only valid in full-duplex mode.
0 = receive frame is not an unsupported control frame
1 = receive frame is a control frame that is not supported (i.e., one that contains an op code field that is not
supported or one that is not equal to the 64-Byte minimum frame size)
CTRL, Control Frame. This bit is only valid in full-duplex mode.
0 = receive frame is not a control frame
1 = receive frame is a control frame
LEN, Length Error. The frame length check is performed only when type/length field contains frame length (TYPE
= 0). When the data field contains more bytes than specified in the length field, these bytes are assumed to be pad
bytes.
0 = receive frame passed the frame length check
1 = receive frame contained fewer bytes than specified in the length field
31
23
15
7
VLAN2
RUNT
MF
VLAN1
WDOG
PF
CRC
FF
DRIB
BCF
FLEN [7:0]
66 of 97
MII_ER
MCF
FLEN [13:8]
UCTRL
TYPE
CTRL
COL
LONG
LEN
24
16
8
0

Related parts for DS80C400