1893AFLF IDT, 1893AFLF Datasheet - Page 22

no-image

1893AFLF

Manufacturer Part Number
1893AFLF
Description
Ethernet ICs 3.3V 10/100 BASE TX INTEGRATED PHYCEIVER
Manufacturer
IDT
Type
Integrated PHY Transceiverr
Datasheet

Specifications of 1893AFLF

Rohs
yes
Product
Ethernet Transceivers
Data Rate
10 Mb/s, 100 Mb/s
Supply Voltage - Max
3.47 V
Supply Voltage - Min
3.14 V
Maximum Operating Temperature
+ 70 C
Package / Case
SSOP-48
Ethernet Connection Type
100Base-TX, 10Base-T
Maximum Supply Current
160 mA
Minimum Operating Temperature
0 C
Standard Supported
802.3
Part # Aliases
ICS1893AFLF
5.3 Automatic Power-Saving Operations
5.4 Auto-Negotiation Operations
ICS1893AF, Rev D 10/26/04
The ICS1893AF has power-saving features that automatically minimize its total power consumption while it
is operating.
Table 5-1. Automatic Power-Saving Features, 10Base-T and 100Base-TX Modes
The ICS1893AF has an Auto-Negotiation sublayer and provides a Control Register bit (bit 0.12) to
determine whether its Auto-Negotiation sublayer is enabled or disabled.
When enabled, the ICS1893AF Auto-Negotiation sublayer exchanges technology capability data with its
remote link partner and automatically selects the highest-performance operating mode it has in common
with its remote link partner. For example, if the ICS1893AF supports 100Base-TX and 10Base-T modes –
but its link partner supports 100Base-TX and 100Base-T4 modes – the two devices automatically select
100Base-TX as the highest-performance common operating mode. For details regarding initialization and
control of the auto-negotiation process, see
Disable Inter-
nal Modules
STA Control
of Automatic
Power-
Saving
Features
Feature
Power-
Saving
ICS1893AF Data Sheet - Release
Table 5-1
In 10Base-T mode, the ICS1893AF
disables all its internal 100Base-TX
modules.
When an STA sets the state of the
ICS1893AF Extended Control Register 2,
bit 19.0 to logic:
Zero, the 100Base-TX modules always
remain enabled, even during 10Base-T
operations.
One, the ICS1893AF automatically
disables 100Base-TX modules while the
ICS1893AF is operating in 10Base-T
mode.
lists the ICS1893AF automatic power-saving features for the various modes.
Copyright © 2004, Integrated Circuit Systems, Inc.
10Base-T Mode
All rights reserved.
Section 7.2, “Functional Block:
22
Mode for ICS1893AF
In 100Base-TX mode, the ICS1893AF
disables all its internal 10Base-T modules.
When an STA sets the state of the
ICS1893AF Extended Control Register 2,
bit 19.1 to logic:
Zero, the 10Base-T modules always
remain enabled, even during
100Base-TX operations.
One, the ICS1893AF automatically
disables 10Base-T modules while the
ICS1893AF is operating in 100Base-TX
mode.
Chapter 5 Operating Modes Overview
100Base-TX Mode
Auto-Negotiation”.
October, 2004