1893AFLF IDT, 1893AFLF Datasheet - Page 76

no-image

1893AFLF

Manufacturer Part Number
1893AFLF
Description
Ethernet ICs 3.3V 10/100 BASE TX INTEGRATED PHYCEIVER
Manufacturer
IDT
Type
Integrated PHY Transceiverr
Datasheet

Specifications of 1893AFLF

Rohs
yes
Product
Ethernet Transceivers
Data Rate
10 Mb/s, 100 Mb/s
Supply Voltage - Max
3.47 V
Supply Voltage - Min
3.14 V
Maximum Operating Temperature
+ 70 C
Package / Case
SSOP-48
Ethernet Connection Type
100Base-TX, 10Base-T
Maximum Supply Current
160 mA
Minimum Operating Temperature
0 C
Standard Supported
802.3
Part # Aliases
ICS1893AFLF
8.7 Register 5: Auto-Negotiation Link Partner Ability Register
8.7.1 Next Page (bit 5.15)
ICS1893AF, Rev D 10/26/04
Table 8-12
determine the capabilities being advertised by the remote link partner. During the auto-negotiation process,
the ICS1893AF advertises (that is, exchanges) the capability data with its remote link partner using a
pre-defined Link Code Word. The value of the Link Control Word received from its remote link partner
establishes the value of the bits in this register.
Note:
1. For an explanation of acronyms used in
2. The values in this register are valid only when the auto-negotiation process is complete, as indicated by
Table 8-12. Auto-Negotiation Link Partner Ability Register (register 5 [0x05])
† As per the IEEE Std 802.3u, during any write operation to any bit in this register, the STA must write the default value
If bit 5.15 is logic:
5.15
5.14
5.13
5.12
5.11
5.10
5.9
5.8
5.7
5.6
5.5
5.4
5.3
5.2
5.1
5.0
Bit
to all Reserved bits.
Zero, then the remote link partner is indicating that this is the last page being transmitted.
One, then the remote link partner is indicating that additional pages follow.
bit 1.5 or bit 17.4.
ICS1893AF Data Sheet - Release
Next Page
Acknowledge
Remote fault
IEEE reserved
IEEE reserved
IEEE reserved
100Base-T4
100Base-TX, full duplex
100Base-TX, half duplex Link partner is not capable
10Base-T, full duplex
10Base-T, half duplex
Selector Field bit S4
Selector Field bit S3
Selector Field bit S2
Selector Field bit S1
Selector Field bit S0
lists the bits for the Auto-Negotiation Link Partner Ability Register. An STA uses this register to
Definition
Copyright © 2004, Integrated Circuit Systems, Inc.
Next Page disabled
Always 0
No faults detected
Always 0
Always 0
Always 0
Always 0. (Not supported.)
Link partner is not capable
Link partner is not capable
Link partner is not capable
IEEE 802.3 defined. Always 0. N/A
IEEE 802.3 defined. Always 0. N/A
IEEE 802.3 defined. Always 0. N/A
IEEE 802.3 defined. Always 0. N/A
N/A
When Bit = 0
All rights reserved.
Table
76
8-12, see
N/A
Remote fault detected
N/A
N/A
N/A
N/A
Link partner is capable
Link partner is capable
Chapter 1, “Abbreviations and
Next Page enabled
Link partner is capable
Link partner is capable
IEEE 802.3 defined.
Always 1.
When Bit = 1
Chapter 8 Management Register Set
cess
CW
CW
CW
CW
Ac-
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
SF
Acronyms”.
October, 2004
fault
De-
0†
0†
0†
0
0
0
0
0
0
0
0
0
0
0
0
0
Hex
0
0
0
0

Related parts for 1893AFLF