1893AFLF IDT, 1893AFLF Datasheet - Page 72

no-image

1893AFLF

Manufacturer Part Number
1893AFLF
Description
Ethernet ICs 3.3V 10/100 BASE TX INTEGRATED PHYCEIVER
Manufacturer
IDT
Type
Integrated PHY Transceiverr
Datasheet

Specifications of 1893AFLF

Rohs
yes
Product
Ethernet Transceivers
Data Rate
10 Mb/s, 100 Mb/s
Supply Voltage - Max
3.47 V
Supply Voltage - Min
3.14 V
Maximum Operating Temperature
+ 70 C
Package / Case
SSOP-48
Ethernet Connection Type
100Base-TX, 10Base-T
Maximum Supply Current
160 mA
Minimum Operating Temperature
0 C
Standard Supported
802.3
Part # Aliases
ICS1893AFLF
8.6 Register 4: Auto-Negotiation Register
8.6.1 Next Page (bit 4.15)
8.6.2 IEEE Reserved Bit (bit 4.14)
ICS1893AF, Rev D 10/26/04
Table 8-11
ICS1893AF capabilities that it wants to advertise to its remote link partner. During the auto-negotiation
process, the ICS1893AF advertises (that is, exchanges) capability data with its remote link partner by using
a pre-defined Link Code Word. The Link Code Word is embedded in the Fast Link Pulses exchanged
between PHYs when the ICS1893AF has its Auto-Negotiation sublayer enabled. The value of the Link
Control Word is established based on the value of the bits in this register.
Note:
Table 8-11. Auto-Negotiation Advertisement Register (register 4 [0x04])
† As per the IEEE Std 802.3u, during any write operation to any bit in this register, the STA must write the default value
This bit indicates whether the ICS1893AF uses the Next Page Mode functions during the auto-negotiation
process. If bit 4.15 is logic:
The ISO/IEC specification reserves this bit for future use. However, the ISO/IEC Standard also defines bit
4.14 as the Acknowledge bit.
4.15
4.14
4.13
4.12
4.10
4.11
4.9
4.8
4.7
4.6
4.5
4.4
4.3
4.2
4.1
4.0
Bit
to all Reserved bits.
Zero, then the ICS1893AF indicates to its remote link partner that these features are disabled. (Although
the default value of this bit is logic zero, the ICS1893AF does support the Next Page function.)
One, then the ICS1893AF advertises to its remote link partner that this feature is enabled.
ICS1893AF Data Sheet - Release
Next Page
IEEE reserved
Remote fault
IEEE reserved
IEEE reserved
IEEE reserved
100Base-T4
100Base-TX, full duplex
100Base-TX, half duplex Do not advertise ability
10Base-T, full duplex
10Base-T half duplex
Selector Field bit S4
Selector Field bit S3
Selector Field bit S2
Selector Field bit S1
Selector Field bit S0
For an explanation of acronyms used in
lists the bits for the Auto-Negotiation Register. An STA uses this register to select the
Definition
Copyright © 2004, Integrated Circuit Systems, Inc.
Next page not supported
Always 0
Locally, no faults detected
Always 0
Always 0
Always 0
Always 0. (Not supported.)
Do not advertise ability
Do not advertise ability
Do not advertise ability
IEEE 802.3-specified default N/A
IEEE 802.3-specified default N/A
IEEE 802.3-specified default N/A
IEEE 802.3-specified default N/A
N/A
When Bit = 0
All rights reserved.
72
Table
8-5, see
Next page supported
N/A
Local fault detected
N/A
N/A
N/A
N/A
Advertise ability
Advertise ability
Advertise ability
Advertise ability
IEEE 802.3-specified
default
When Bit = 1
Chapter 1, “Abbreviations and
Chapter 8 Management Register Set
cess
R/W
R/W
R/W
R/W
R/W
R/W
CW
CW
CW
CW
CW
CW
CW
CW
CW
Ac-
CW
SF
October, 2004
Acronyms”.
fault
De-
0†
0†
0†
0†
0
0
0
1
1
1
1
0
0
0
0
1
Hex
0
1
E
1