HD6417720BP133BV Renesas Electronics America, HD6417720BP133BV Datasheet - Page 1006

SH3-DSP, WITH USB AND LCDC, PB-F

HD6417720BP133BV

Manufacturer Part Number
HD6417720BP133BV
Description
SH3-DSP, WITH USB AND LCDC, PB-F
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417720BP133BV

Core Processor
SH-3 DSP
Core Size
32-Bit
Speed
133MHz
Connectivity
FIFO, I²C, IrDA, MMC, SCI, SD, SIO, SIM, USB
Peripherals
DMA, LCD, POR, WDT
Number Of I /o
117
Program Memory Type
ROMless
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
1.4 V ~ 1.6 V
Data Converters
A/D 4x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
256-BGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-
Section 27 A/D Converter
27.7
27.7.1
(1)
Problem: Even though the ADCSR.ADF bit has been read as 1 and 0 was then written to the ADF
bit, the ADF bit has not been cleared to 0.
Condition: This problem arises when reading of the ADF bit coincides with setting of the bit to 1
upon the end of A/D conversion.
Avoiding the Problem: Follow any of procedures (a), (b), or (c) below.
(2)
Problem: A/D conversion in scan mode is not stopped by clearing the ADCSR.ADST bit (to 0).
Condition: This problem arises when 0 is written to the ADST bit in ADCSR to stop A/D
conversion while A/D conversion in scan mode is in progress.
Avoiding the Problem: Place the ADC in module standby state after clearing the ADST bit (to 0).
Placing the ADC in the module standby state initializes the ADC and stops A/D conversion. When
further A/D conversion is required, restart A/D conversion after releasing the ADC from the
module standby state.
Page 946 of 1414
(a) Ensure that setting of the ADF bit to 1 upon the end of A/D conversion does not coincide
(b) If the ADF bit has not been cleared, repeat the operation of reading it as 1 and then
(c) Initialize the ADC and clear the ADF bit by placing the ADC in the module standby state.
Notes on Clearing the ADF Bit in the ADCSR Register
Notes on A/D Conversion in Scan Mode
with reading of the ADF bit. For example, read the ADF bit as 1 and then write 0 to the
bit during processing of the A/D conversion end interrupt (ADI) that is generated at the
end of A/D conversion (when the ADF is set to 1).
writing 0 to it.
Usage Notes
Notes on A/D Conversion
SH7720 Group, SH7721 Group
R01UH0083EJ0400 Rev. 4.00
Sep 21, 2010

Related parts for HD6417720BP133BV