Specifications of ISP1761BE

Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Operating Temperature (max)
85C
Package Type
LQFP
Rad Hardened
No
Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISP1761BE
Manufacturer:
ST
0
Part Number:
ISP1761BE
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
ISP1761BE
Quantity:
56
Company:
Part Number:
ISP1761BE
Quantity:
1 000
Part Number:
ISP1761BE-S
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
Part Number:
ISP1761BEGE
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
Part Number:
ISP1761BEUM
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
NXP Semiconductors
Table 74.
ISP1761_5
Product data sheet
Bit
41 to 35
34 to 32
DW0
31
30 to 29
28 to 18
17 to 3
2 to 1
0
Symbol
Device
Address[6:0]
EndPt[3:1]
EndPt[0]
reserved
TT_MPS_Len
[10:0]
NrBytesTo
Transfer[14:0]
reserved
V
Start and complete split for isochronous: bit description
Access
SW — writes
SW — writes
SW — writes
-
SW — writes
SW — writes
-
SW — sets
HW — resets
Rev. 05 — 13 March 2008
Value Description
-
-
-
-
-
-
-
-
Device Address: This is the USB address of the function
containing the endpoint that is referred to by this buffer.
Endpoint: This is the USB address of the endpoint within the
function.
Endpoint: This is the USB address of the endpoint within the
function.
-
Transaction Translator Maximum Packet Size Length: This
field indicates the maximum number of bytes that can be sent
per start split depending on the number of total bytes needed. If
the total bytes to be sent for the entire millisecond is greater
than 188 bytes, this field should be set to 188 bytes for an OUT
token and 192 bytes for an IN token. Otherwise, this field
should be equal to the total bytes sent.
Number of Bytes to Transfer: This field indicates the number
of bytes that can be transferred by this data structure. It is used
to indicate the depth of the DATA field. This field is restricted to
1023 bytes because in siTD the maximum allowable payload for
a full-speed device is 1023 bytes. This field indirectly becomes
the maximum packet size of the downstream device.
-
0 — This bit is deactivated when the entire PTD is executed, or
when a fatal error is encountered.
1 — Software updates to one when there is payload to be sent
or received. The current PTD is active.
…continued
Hi-Speed USB OTG controller
© NXP B.V. 2008. All rights reserved.
ISP1761
80 of 163