ep2s130 Altera Corporation, ep2s130 Datasheet - Page 108

no-image

ep2s130

Manufacturer Part Number
ep2s130
Description
Stratix Ii Device Family Data Sheet
Manufacturer
Altera Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ep2s130F1020
Manufacturer:
ALTERA
0
Part Number:
ep2s130F102015N
Manufacturer:
ALTERA
0
Part Number:
ep2s130F1020C
Manufacturer:
ALTERA
0
Part Number:
ep2s130F1020C3
Manufacturer:
Altera
Quantity:
10 000
Part Number:
ep2s130F1020C3
Manufacturer:
ALTERA
0
Part Number:
ep2s130F1020C3N
Manufacturer:
ALTERA
Quantity:
238
Part Number:
ep2s130F1020C3N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
ep2s130F1020C3N
0
Part Number:
ep2s130F1020C4
Manufacturer:
ALTERA
Quantity:
748
Part Number:
ep2s130F1020C4
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
ep2s130F1020C4N
Manufacturer:
HYUNDAI
Quantity:
1 730
Part Number:
ep2s130F1020C4N
Manufacturer:
ALTERA
Quantity:
3 000
High-Speed Differential I/O with DPA Support
Figure 2–58. Stratix II Transmitter Channel
2–100
Stratix II Device Handbook, Volume 1
refclk
Fast
PLL
Dedicated Circuitry with DPA Support
Stratix II devices support source-synchronous interfacing with LVDS or
HyperTransport signaling at up to 1 Gbps. Stratix II devices can transmit
or receive serial channels along with a low-speed or high-speed clock.
The receiving device PLL multiplies the clock by an integer factor W = 1
through 32. For example, a HyperTransport technology application
where the data rate is 1,000 Mbps and the clock rate is 500 MHz would
require that W be set to 2. The SERDES factor J determines the parallel
data width to deserialize from receivers or to serialize for transmitters.
The SERDES factor J can be set to 4, 5, 6, 7, 8, 9, or 10 and does not have to
equal the PLL clock-multiplication W value. A design using the dynamic
phase aligner also supports all of these J factor values. For a J factor of 1,
the Stratix II device bypasses the SERDES block. For a J factor of 2, the
Stratix II device bypasses the SERDES block, and the DDR input and
output registers are used in the IOE.
of the Stratix II transmitter channel.
Each Stratix II receiver channel features a DPA block for phase detection
and selection, a SERDES, a synchronizer, and a data realigner circuit. You
can bypass the dynamic phase aligner without affecting the basic source-
synchronous operation of the channel. In addition, you can dynamically
switch between using the DPA block or bypassing the block via a control
signal from the logic array.
Stratix II receiver channel.
Data from R4, R24, C4, or
direct link interconnect
Interconnect
Local
diffioclk
load_en
10
10
Figure 2–59
Figure 2–58
shows the block diagram of the
Dedicated
Transmitter
Interface
+
shows the block diagram
Regional or
global clock
Up to 1 Gbps
Altera Corporation
May 2007

Related parts for ep2s130