ep2s130 Altera Corporation, ep2s130 Datasheet - Page 157

no-image

ep2s130

Manufacturer Part Number
ep2s130
Description
Stratix Ii Device Family Data Sheet
Manufacturer
Altera Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ep2s130F1020
Manufacturer:
ALTERA
0
Part Number:
ep2s130F102015N
Manufacturer:
ALTERA
0
Part Number:
ep2s130F1020C
Manufacturer:
ALTERA
0
Part Number:
ep2s130F1020C3
Manufacturer:
Altera
Quantity:
10 000
Part Number:
ep2s130F1020C3
Manufacturer:
ALTERA
0
Part Number:
ep2s130F1020C3N
Manufacturer:
ALTERA
Quantity:
238
Part Number:
ep2s130F1020C3N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
ep2s130F1020C3N
0
Part Number:
ep2s130F1020C4
Manufacturer:
ALTERA
Quantity:
748
Part Number:
ep2s130F1020C4
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
ep2s130F1020C4N
Manufacturer:
HYUNDAI
Quantity:
1 730
Part Number:
ep2s130F1020C4N
Manufacturer:
ALTERA
Quantity:
3 000
Altera Corporation
May 2007
Preliminary status means the timing model is subject to change. Initially,
timing numbers are created using simulation results, process data, and
other known parameters. These tests are used to make the preliminary
numbers as close to the actual timing parameters as possible.
Final timing numbers are based on actual device operation and testing.
These numbers reflect the actual performance of the device under
worst-case voltage and junction temperature conditions.
I/O Timing Measurement Methodology
Altera characterizes timing delays at the worst-case process, minimum
voltage, and maximum temperature for input register setup time (t
and hold time (t
to calculate t
Figure 5–3
Table 5–33. Stratix II Device Timing Model Status
t
t
SU
H
= – data delay from input pin to input register
EP2S130
EP2S180
= + data delay from input pin to input register
EP2S15
EP2S30
EP2S60
EP2S90
Device
+ micro setup time of the input register
– clock delay from input pin to input register
+ micro hold time of the input register
+ clock delay from input pin to input register
shows the setup and hold timing diagram for input registers.
SU
and t
H
). The Quartus II software uses the following equations
H
timing for Stratix II devices input signals.
Preliminary
Stratix II Device Handbook, Volume 1
DC & Switching Characteristics
Final
v
v
v
v
v
v
SU
5–21
)

Related parts for ep2s130