HD64F3337YCP16V Renesas Electronics America, HD64F3337YCP16V Datasheet - Page 491

MCU 3/5V 60K PB-FREE 84-PLCC

HD64F3337YCP16V

Manufacturer Part Number
HD64F3337YCP16V
Description
MCU 3/5V 60K PB-FREE 84-PLCC
Manufacturer
Renesas Electronics America
Series
H8® H8/300r
Datasheets

Specifications of HD64F3337YCP16V

Core Size
8-Bit
Program Memory Size
60KB (60K x 8)
Oscillator Type
Internal
Core Processor
H8/300
Speed
16MHz
Connectivity
Host Interface, I²C, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
74
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Operating Temperature
-20°C ~ 75°C
Package / Case
84-PLCC
No. Of I/o's
74
Ram Memory Size
1KB
Cpu Speed
16MHz
No. Of Timers
6
No. Of Pwm Channels
2
Digital Ic Case Style
PLCC
Controller Family/series
H8/300
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3337YCP16V
Manufacturer:
COILMASTER
Quantity:
30 000
Part Number:
HD64F3337YCP16V
Manufacturer:
RENESAS
Quantity:
1 029
Part Number:
HD64F3337YCP16V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Sample Block-Erase Program: This program uses the following registers.
R0:
R1H: Stores data to be read, and also used for dummy write.
R2:
R3:
R4:
R5:
R6L: Used for prewrite-verify and erase-verify fail count.
The setting of #a, #b, #c, #d, and #e values in the program depends on the clock frequency. Set #a,
#b, #c, #d, and #e values according tables 20.9 (1) and (2), and 20.10. Erase block registers (EBR1
and EBR2) should be set according to sections 20.2.2 and 20.2.3. #BLKSTR and #BLKEND are
the top and last addresses of the block to be erased. Set #BLKSTR and #BLKEND according to
figure 20.2.
Specifies block to be erased, and also stores address used in prewrite and erase-verify.
Stores last address of block to be erased.
Stores address used in prewrite and erase-verify.
Sets timing loop counters for prewrite, prewrite-verify, erase, and erase-verify, and also
stores register setting value.
Sets prewrite and erase timing loop counters.
459