Specifications of WM8352GEB/V

Number Of Adc Inputs
2
Number Of Dac Outputs
2
Conversion Rate
48 KSPS
Interface Type
Serial (2-Wire, 3-Wire, 4-Wire)
Resolution
12 bit
Operating Supply Voltage
3.7 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
BGA
Minimum Operating Temperature
- 25 C
Number Of Channels
2 ADC/2 DAC
Supply Current
260 uA
Thd Plus Noise
- 83 dB
Audio Codec Type
Stereo
No. Of Adcs
2
No. Of Dacs
2
No. Of Input Channels
8
No. Of Output Channels
6
Adc / Dac Resolution
24bit
Adcs / Dacs Signal To Noise Ratio
95dB
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Production Data
w
R20 (14h)
ALARM
sec / min
R21 (15h)
ALARM
hour / day
R22 (16h)
ALARM
date
Table 132 RTC Alarm Registers
The “don’t care” option (all bits set to 1) provides extra flexibility for programming ALARM duration
and recurrent alarms. For example:
ADDRESS
Setting only RTC_ALMSEC to “don’t care” produces an alarm lasting 1 minute.
Setting only RTC_ALMDATE to “don’t care” produces an alarm lasting 1 second that
recurs once a week, on the day determined by RTC_ALMDAY, during the month
determined by RTC_ALMMTH.
Setting RTC_ALMSEC, RTC_ALMDATE, RTC_ALMDAY and RTC_ALMMTH to “don’t
care” produces a daily alarm lasting 1 minute.
14:8
11:8
12:8
BIT
6:0
4:0
5:0
5
RTC_ALMMINS
[6:0]
RTC_ALMSECS
[6:0]
RTC_ALMDAY
[3:0]
RTC_ALMHPM
RTC_ALMHRS
[4:0]
RTC_ALMMTH
[4:0]
RTC_ALMDATE
[5:0]
LABEL
DEFAULT
000_0000
000_0000
00_0000
0_0000
0_0000
0000
0
Minutes alarm register with range 0-59. All
1's sets to 'don't care' state.
Note, during programming it is best to
disable the Alarm Enable request bit to
avoid false alarms.
Seconds alarm register with range 0-59. All
1's set to 'don't care' state.
Note, during programming it is best to
disable the Alarm Enable request bit to
avoid false alarms.
Day alarm register, with range 1-7, 1 =
Sunday. All 1's sets to 'don't care' state.
Note, during programming it is best to
disable the Alarm Enable request bit to
avoid false alarms.
Alarm hours AM/PM flag
0 = AM
1 = PM
Only applicable in 12 hour mode. In 24 hour
mode set to 1 if RTC_ALMHRS is set to all
1’s ‘don’t care’ or 0 otherwise.
Hours alarm register with range 0-23 in 24
hours mode and 1-12 in 12 hour. In 12 hour
mode bit 5 is used as PM/not-AM flag. All
1's sets to 'don't care' state.
Note, during programming it is best to
disable the Alarm Enable request bit to
avoid false alarms.
Month alarm register with range 1-12. All
1's sets to 'don't care' state.
Note, during programming it is best to
disable the Alarm Enable request bit to
avoid false alarms.
Date alarm register with range 1-31. All 1's
sets to 'don't care' state.
Note, during programming it is best to
disable the Alarm Enable request bit to
avoid false alarms.
DESCRIPTION
PD, March 2010, Rev 4.2
WM8352