Specifications of WM8352GEB/V

Number Of Adc Inputs
2
Number Of Dac Outputs
2
Conversion Rate
48 KSPS
Interface Type
Serial (2-Wire, 3-Wire, 4-Wire)
Resolution
12 bit
Operating Supply Voltage
3.7 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
BGA
Minimum Operating Temperature
- 25 C
Number Of Channels
2 ADC/2 DAC
Supply Current
260 uA
Thd Plus Noise
- 83 dB
Audio Codec Type
Stereo
No. Of Adcs
2
No. Of Dacs
2
No. Of Input Channels
8
No. Of Output Channels
6
Adc / Dac Resolution
24bit
Adcs / Dacs Signal To Noise Ratio
95dB
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
WM8352
Register 14h Alarm Seconds/Minutes
Register 15h Alarm Hours/Day
Register 16h Alarm Date/Month
w
REGISTER
R20 (14h) Alarm
REGISTER
ADDRESS
ADDRESS
Seconds/Minute
Date/Month
Hours/Day
R21 (15h)
R22 (16h)
REGISTER
ADDRESS
Alarm
Alarm
s
BIT
BIT
11:8
12:8
4:0
5:0
5
BIT
14:8
6:0
RTC_ALMDATE[5:0]
RTC_ALMDAY[3:0]
RTC_ALMHRS[4:0]
RTC_ALMMTH[4:0]
RTC_ALMHPM
RTC_ALMSECS[6:0]
RTC_ALMMINS[6:0]
LABEL
LABEL
LABEL
DEFAULT
DEFAULT
0_0000
00_0000
0_0000
0000
DEFAULT
0
000_0000
000_0000
Day alarm register, with range 1-7, 1 = Sunday.
All 1's sets to 'don't care' state.
Note, during programming it is best to disable the
Alarm Enable request bit to avoid false alarms.
Alarm hours AM/PM flag
0 = AM
1 = PM
Only applicable in 12 hour mode. In 24 hour mode
set to 1 if RTC_ALMHRS is set to all 1’s ‘don’t
care’ or 0 otherwise.
Hours alarm register with range 0-23 in 24 hours
mode and 1-12 in 12 hour. In 12 hour mode bit 5 is
used as PM/not-AM flag. All 1's sets to 'don't care'
state.
Note, during programming it is best to disable the
Alarm Enable request bit to avoid false alarms.
Month alarm register with range 1-12. All 1's sets
to 'don't care' state.
Note, during programming it is best to disable the
Alarm Enable request bit to avoid false alarms.
Date alarm register with range 1-31. All 1's sets to
'don't care' state.
Note, during programming it is best to disable the
Alarm Enable request bit to avoid false alarms.
Minutes alarm register with range 0-59. All 1's
sets to 'don't care' state.
Note, during programming it is best to disable
the Alarm Enable request bit to avoid false
alarms.
Seconds alarm register with range 0-59. All 1's
set to 'don't care' state.
Note, during programming it is best to disable
the Alarm Enable request bit to avoid false
alarms.
DESCRIPTION
DESCRIPTION
DESCRIPTION
PD, March 2010, Rev 4.2
REFER TO
REFER TO
REFER TO
Production Data