WM8352GEB/V Wolfson Microelectronics, WM8352GEB/V Datasheet - Page 243

Audio CODECs Audio CODEC plus pwr management

WM8352GEB/V

Manufacturer Part Number
WM8352GEB/V
Description
Audio CODECs Audio CODEC plus pwr management
Manufacturer
Wolfson Microelectronics
Datasheet

Specifications of WM8352GEB/V

Number Of Adc Inputs
2
Number Of Dac Outputs
2
Conversion Rate
48 KSPS
Interface Type
Serial (2-Wire, 3-Wire, 4-Wire)
Resolution
12 bit
Operating Supply Voltage
3.7 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
BGA
Minimum Operating Temperature
- 25 C
Number Of Channels
2 ADC/2 DAC
Supply Current
260 uA
Thd Plus Noise
- 83 dB
Audio Codec Type
Stereo
No. Of Adcs
2
No. Of Dacs
2
No. Of Input Channels
8
No. Of Output Channels
6
Adc / Dac Resolution
24bit
Adcs / Dacs Signal To Noise Ratio
95dB
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Production Data
REGISTER
Register 27h Comparator Interrupt Status Mask
Register 28h Clock Control 1
w
REGISTER
ADDRESS
ADDRESS
R40 (28h)
Control 1
Clock
BIT
BIT
0
7:4
2:0
15
14
11
8
IM_WKUP_GP_WAKEUP_EINT
OPCLK_DIV[2:0]
BCLK_DIV[3:0]
TOCLK_RATE
TOCLK_ENA
MCLK_SEL
MCLK_DIV
LABEL
LABEL
DEFAULT
0100
000
0
0
0
0
Slow clock enable. Used for both the jack insert
detect debounce circuit and the zero cross timeout.
0 = slow clock disabled
1 = slow clock enabled
Slow Clock Selection (Used for volume update
timeouts and for jack detect debounce)
0 = SYSCLK / 2^21 (Slower Response)
1 = SYSCLK / 2^19 (Faster Response)
Selects source for SYSCLK to CODEC
0 = MCLK pin
1 = FLL
Selects MCLK division in slave (MCLK input) mode:
0 = divide MCLK by 1
1 = divide MCLK by 2
Sets BCLK rate for Master mode
0000 = SYSCLK
0001 = SYSCLK / 1.5
0010 = SYSCLK / 2
0011 = SYSCLK / 3
0100 = SYSCLK / 4
0101 = SYSCLK / 5.5
0101 = SYSCLK / 6
0111 = SYSCLK / 8
1000 = SYSCLK / 11
1001 = SYSCLK / 12
1010 = SYSCLK / 16
1011 = SYSCLK / 22
1100 = SYSCLK / 24
1101 = SYSCLK / 32
1110 = SYSCLK / 32
1111 = SYSCLK / 32
OPCLK Frequency (GPIO function)
000 = SYSCLK
001 = SYSCLK / 2
010 = SYSCLK / 3
011 = SYSCLK / 4
100 = SYSCLK / 5.5
101 = SYSCLK / 6
110 = Reserved
111 = Reserved
DEFAULT
0
Reset by state machine.
Interrupt mask.
0 = Do not mask interrupt.
1 = Mask interrupt.
Reset by state machine.
DESCRIPTION
DESCRIPTION
PD, March 2010, Rev 4.2
REFER TO
REFER TO
WM8352
243