WM8352GEB/V Wolfson Microelectronics, WM8352GEB/V Datasheet - Page 307

Audio CODECs Audio CODEC plus pwr management

WM8352GEB/V

Manufacturer Part Number
WM8352GEB/V
Description
Audio CODECs Audio CODEC plus pwr management
Manufacturer
Wolfson Microelectronics
Datasheet

Specifications of WM8352GEB/V

Number Of Adc Inputs
2
Number Of Dac Outputs
2
Conversion Rate
48 KSPS
Interface Type
Serial (2-Wire, 3-Wire, 4-Wire)
Resolution
12 bit
Operating Supply Voltage
3.7 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
BGA
Minimum Operating Temperature
- 25 C
Number Of Channels
2 ADC/2 DAC
Supply Current
260 uA
Thd Plus Noise
- 83 dB
Audio Codec Type
Stereo
No. Of Adcs
2
No. Of Dacs
2
No. Of Input Channels
8
No. Of Output Channels
6
Adc / Dac Resolution
24bit
Adcs / Dacs Signal To Noise Ratio
95dB
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Production Data
REGISTER
Register CAh LDO1 Low Power
Register CBh LDO2 Control
Register CCh LDO2 Timeouts
w
REGISTER
REGISTER
ADDRESS
ADDRESS
ADDRESS
R204 (CCh)
R203 (CBh)
Timeouts
Control
LDO2
LDO2
15:14
13:10
BIT
BIT
BIT
4:0
9:6
14
10
LDO2_VSEL[4:0]
LDO2_ERRACT[1:0]
LDO2_ENSLOT[3:0]
LDO2_SDSLOT[3:0]
LDO2_OPFLT
LDO2_SWI
LABEL
LABEL
LABEL
DEFAULT
1_1011
1_1010
0_0110
1_0111
DEFAULT
0
0
DEFAULT
0000
0000
0001
0100
0000
00
LDO2 Regulator mode
0 = LDO voltage regulator
1 = Current-limited switch (no voltage regulation,
LDO2_VSEL has no effect)
Reset by state machine. Default held in metal mask.
Enable discharge of LDO2 outputs when LDO2 is
disabled
0 = Enabled - Output to be discharged
1 = Disabled - Output is left floating
Note - if LDO Regulators 1, 2, 3 and 4 are all
disabled, then the outputs will all be discharged,
regardless of the LDOn_OPFLT bit.
LDO2 Regulator output voltage (when LDO2_SWI=0)
1 1111 = 3.3V
… (100mV steps)
1 0000 = 1.8V
0 1111 = 1.65V
… (50mV steps)
0 0000 = 0.9V
Reset by state machine. Default held in metal mask.
Action to take on LDO2 fault (as well as
generating an interrupt):
00 = ignore
01 = shut down regulator
10 = shut down system
11 = reserved (shut down system)
Reset by state machine. Default held in metal
mask.
Time slot for LDO2 start-up
0000 = Disabled (do not start up)
0001 = Start-up in time slot 1
… (total 14 slots available)
1110 = Start-up in time slot 14
1111 = Start up on entering ACTIVE
Reset by state machine. Default held in metal
mask.
Time slot for LDO2 shutdown.
0000 = Shut down on entering OFF
0001 = Shutdown in time slot 1
…. (total 14 slots available)
1110 = Shutdown in time slot 14
1111 = Shut down on entering OFF
0 0000 = 0.9V
DESCRIPTION
DESCRIPTION
DESCRIPTION
PD, March 2010, Rev 4.2
REFER TO
REFER TO
REFER TO
WM8352
307