XE8805AMI028LF Semtech, XE8805AMI028LF Datasheet - Page 80

IC DAS 16BIT FLASH 8K MTP 64LQFP

XE8805AMI028LF

Manufacturer Part Number
XE8805AMI028LF
Description
IC DAS 16BIT FLASH 8K MTP 64LQFP
Manufacturer
Semtech
Datasheet

Specifications of XE8805AMI028LF

Applications
Sensing Machine
Core Processor
RISC
Program Memory Type
FLASH (22 kB)
Controller Series
XE8000
Ram Size
512 x 8
Interface
UART, USRT
Number Of I /o
24
Voltage - Supply
2.4 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
64-LQFP
Supply Voltage Range
2.4V To 5.5V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
LQFP
No. Of Pins
64
For Use With
XE8000MP - PROG BOARD AND PROSTART2 CARD
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XE8805AMI028LF
Manufacturer:
Semtech
Quantity:
10 000
Part Number:
XE8805AMI028LF
Manufacturer:
SEMTECH/美国升特
Quantity:
20 000
14.8 Software hints
Example of program for a transmission with polling:
1. The RegUartCmd register and the RegUartCtrl register are initialized (for example: 8 bit word length, odd
2. Write a byte to RegUartTx.
3. Wait until the UartTxFull bit in RegUartTxSta register equals 0.
4. Jump to 2 to write the next byte if the message is not finished.
5. End of transmission.
Example of program for a transmission with interrupt:
1. The RegUartCmd register and the RegUartCtrl register are initialized (for example: 8 bit word length, odd
2. Write a byte to RegUartTx.
3. After an interrupt and if the message is not finished, jump to 2
4. End of transmission.
Example of program for a reception with polling:
1. The RegUartCmd register and the RegUartCtrl register are initialized (for example: 8 bit word length, odd
2. Wait until the UartRxFull bit in the RegUartRxSta register equals 1.
3. Read the RegUartRxSta and check if there is no error.
4. Read data in RegUartRx.
5. If data is not equal to End-Of-Line, then jump to 2.
6. End of reception.
Example of program for a reception with interrupt:
1. The RegUartCmd register and the RegUartCtrl register are initialized (for example: 8 bit word length, odd
2. When there is an interrupt, jump to 3
3. Read RegUartRxSta and check if there is no error.
4. Read data in RegUartRx.
5. If data is not equal to End-Of-Line, then jump to 2.
6. End of reception.
© Semtech 2006
parity, 9600 baud, enable Uart transmission).
parity, 9600 baud, enable Uart transmission).
parity, 9600 baud, enable Uart reception).
parity, 9600 baud, enable Uart reception).
14-7
XE8805/05A