MC68HC912D60 Motorola, MC68HC912D60 Datasheet - Page 266

no-image

MC68HC912D60

Manufacturer Part Number
MC68HC912D60
Description
Microcontrollers
Manufacturer
Motorola
Datasheet
Multiple Serial Interface
15.4.1 Data Format
15.4.2 SCI Baud Rate Generation
Technical Data
266
The serial data format requires the following conditions:
The basis of the SCI baud rate generator is a 13-bit modulus counter.
This counter gives the generator the flexibility necessary to achieve a
reasonable level of independence from the CPU operating frequency
and still be able to produce standard baud rates with a minimal amount
of error. The clock source for the generator comes from the M Clock.
Freescale Semiconductor, Inc.
For More Information On This Product,
An idle-line in the high state before transmission or reception of a
message.
A start bit (logic zero), transmitted or received, that indicates the
start of each character.
Data that is transmitted or received least significant bit (LSB) first.
A stop bit (logic one), used to indicate the end of a frame. (A frame
consists of a start bit, a character of eight or nine data bits and a
stop bit.)
A BREAK is defined as the transmission or reception of a logic
zero for one frame or more.
This SCI supports hardware parity for transmit and receive.
Go to: www.freescale.com
SCI Baud Rate
Multiple Serial Interface
Desired
Table 15-1. Baud Rate Generation
14400
19200
38400
1200
2400
4800
9600
110
300
600
BR Divisor for
M = 4.0 MHz
2273
833
417
208
104
52
26
17
13
BR Divisor for
M = 8.0 MHz
MC68HC912D60A — Rev 3.0
4545
2273
833
417
208
104
52
35
26
13