IC MCU 8BIT OTP 4K 20 PDIP

ST62T20CB6

Manufacturer Part NumberST62T20CB6
DescriptionIC MCU 8BIT OTP 4K 20 PDIP
ManufacturerSTMicroelectronics
SeriesST6
ST62T20CB6 datasheet
 

Specifications of ST62T20CB6

Core ProcessorST6Core Size8-Bit
Speed8MHzPeripheralsLVD, POR, WDT
Number Of I /o12Program Memory Size4KB (4K x 8)
Program Memory TypeOTPRam Size64 x 8
Voltage - Supply (vcc/vdd)3 V ~ 6 VData ConvertersA/D 8x8b
Oscillator TypeInternalOperating Temperature-40°C ~ 85°C
Package / Case20-DIP (0.300", 7.62mm)Controller Family/seriesST6
No. Of I/o's12Ram Memory Size64Byte
Cpu Speed8MHzNo. Of Timers1
Rohs CompliantYesProcessor SeriesST62T2x
CoreST6Data Bus Width8 bit
Data Ram Size64 BMaximum Clock Frequency8 MHz
Number Of Programmable I/os12Number Of Timers2
Operating Supply Voltage3 V to 6 VMaximum Operating Temperature+ 85 C
Mounting StyleThrough HoleDevelopment Tools By SupplierST622XC-KIT/110, ST62GP-EMU2, ST62E2XC-EPB/110, ST62E6XC-EPB/US, STREALIZER-II
Minimum Operating Temperature- 40 COn-chip Adc8 bit
Lead Free Status / RoHS StatusLead free / RoHS CompliantEeprom Size-
Connectivity-Other names497-2098-5
1
2
3
4
5
6
7
8
9
10
11
Page 11
12
Page 12
13
Page 13
14
Page 14
15
Page 15
16
Page 16
17
Page 17
18
Page 18
19
Page 19
20
Page 20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
Page 13/104

Download datasheet (2Mb)Embed
PrevNext
MEMORY MAP (Cont’d)
3.1.6 Data ROM Window
The Data read-only memory window is located
from address 0040h to address 007Fh in Data
space. It allows direct reading of 64 consecutive
bytes located anywhere in program memory, be-
tween address 0000h and 0FFFh.
There are 64 blocks of 64 bytes in a 4K device:
– Block 0 is related to the address range 0000h to
003Fh.
– Block 1 is related to the address range 0040h to
007Fh.
and so on...
All the program memory can therefore be used to
store either instructions or read-only data. The
Data ROM window can be moved in steps of 64
bytes along the program memory by writing the
appropriate code in the Data ROM Window Regis-
ter (DRWR).
Figure 5. Data ROM Window
PROGRAM
SPACE
0000h
64-BYTE
ROM
0FFFh
ST6208C/ST6209C/ST6210C/ST6220C
3.1.6.1 Data ROM Window Register (DRWR)
The DRWR can be addressed like any RAM loca-
tion in the Data Space.
This register is used to select the 64-byte block of
program memory to be read in the Data ROM win-
dow (from address 40h to address 7Fh in Data
space). The DRWR register is not cleared on re-
set, therefore it must be written to before access-
ing the Data read-only memory window area for
the first time.
Address: 0C9h — Write Only
Reset Value = xxh (undefined)
7
-
-
Bits 7:6 = Reserved, must be cleared.
DATA SPACE
000h
Bit 5:0 = DRWR[5:0] Data read-only memory Win-
dow Register Bits. These are the Data read-only
memory Window bits that correspond to the upper
bits of the data read-only memory space.
040h
Caution: This register is undefined on reset, it is
DATA ROM
write-only, therefore do not read it nor access it us-
WINDOW
ing Read-Modify-Write instructions (SET, RES,
07Fh
INC and DEC).
0FFh
DRWR5 DRWR4 DRWR3 DRWR2 DRWR1 DRWR0
0