OM13006,598 NXP Semiconductors, OM13006,598 Datasheet - Page 129

BOARD EVAL EM773 METER EU PLUG

OM13006,598

Manufacturer Part Number
OM13006,598
Description
BOARD EVAL EM773 METER EU PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13006,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6681
NXP Semiconductors
Table 135. Miscellaneous States
UM10415
User manual
Status
Code
(I2CSTAT)
0xF8
0x00
10.11.6.1 Simultaneous Repeated START conditions from two masters
Status of the I
and hardware
No relevant state
information available;
SI = 0.
Bus error during MST
or selected slave
modes, due to an
illegal START or
STOP condition. State
0x00 can also occur
when interference
causes the I
to enter an undefined
state.
10.11.6 Some special cases
2
causes the I
clear the STO flag (no other bits in I2CON are affected). The SDA and SCL lines are
released (a STOP condition is not transmitted).
The I
during a serial transfer:
A Repeated START condition may be generated in the master transmitter or master
receiver modes. A special case occurs if another master simultaneously generates a
Repeated START condition (see
either master since they were both transmitting the same data.
If the I
a Repeated START condition itself, it will release the bus, and no interrupt request is
generated. If another master frees the bus by generating a STOP condition, the I
will transmit a normal START condition (state 0x08), and a retry of the total serial data
transfer can commence.
C block
2
C-bus
Simultaneous Repeated START conditions from two masters
Data transfer after loss of arbitration
Forced access to the I
I
Bus error
2
2
C-bus obstructed by a LOW level on SCL or SDA
C hardware has facilities to handle the following special cases that may occur
2
C hardware detects a Repeated START condition on the I
Application software response
To/From I2DAT
No I2DAT action
No I2DAT action
2
C block to enter the “not addressed” slave mode (a defined state) and to
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 10 September 2010
2
C-bus
To I2CON
STA STO SI
0
No I2CON action
Figure
1
0
27). Until this occurs, arbitration is not lost by
AA
X
Chapter 10: EM773 I2C-bus interface
Next action taken by I
Wait or proceed current transfer.
Only the internal hardware is affected in
the MST or addressed SLV modes. In all
cases, the bus is released and the I
block is switched to the not addressed
SLV mode. STO is reset.
2
C-bus before generating
UM10415
© NXP B.V. 2010. All rights reserved.
2
C hardware
2
129 of 310
C block
2
C