OM13006,598 NXP Semiconductors, OM13006,598 Datasheet - Page 184

BOARD EVAL EM773 METER EU PLUG

OM13006,598

Manufacturer Part Number
OM13006,598
Description
BOARD EVAL EM773 METER EU PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13006,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6681
NXP Semiconductors
15.5 Operation
15.6 Register description
Table 174. Register overview: SysTick timer (base address 0xE000 E000)
[1]
UM10415
User manual
Name
SYST_CSR
SYST_RVR
SYST_CVR
SYST_CAL
Reset Value reflects the data stored in used bits only. It does not include content of reserved bits.
Access
R/W
R/W
R/W
R/W
The SysTick timer is a 24-bit timer that counts down to zero and generates an interrupt.
The intent is to provide a fixed 10 millisecond time interval between interrupts. The
SysTick timer is clocked from the CPU clock. In order to generate recurring interrupts at a
specific interval, the SYST_RVR register must be initialized with the correct value for the
desired interval. A default value (<tbd>) is provided in the SYST_CALIB register and may
be changed by software. The default value gives a 10 millisecond interrupt rate if the CPU
clock is set to <tbd>.
The block diagram of the SysTick timer is shown below in the
The systick timer registers are located on the ARM Cortex-M0 private peripheral bus (see
Figure
Section
Fig 47. System tick timer block diagram
Address
offset
0x010
0x014
0x018
0x01C
55), and are part of the ARM Cortex-M0 core peripherals. For details, see
20.5.4.
system clock/2
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 10 September 2010
System Timer Reload value register
Description
System Timer Control and status register
System Timer Current value register
System Timer Calibration value register
COUNTFLAG
clock
24-bit down counter
load
SYST_CALIB
SYST_RVR
SYST_CVR
SYST_CSR
load data
under-
flow
Chapter 15: EM773 System tick timer
TICKINT
enable
count
ENABLE
Figure
System Tick
interrupt
peripheral
private
47.
UM10415
bus
© NXP B.V. 2010. All rights reserved.
Reset value
0x000 0000
0
0
0x4
184 of 310
[1]