OM13006,598 NXP Semiconductors, OM13006,598 Datasheet - Page 196

BOARD EVAL EM773 METER EU PLUG

OM13006,598

Manufacturer Part Number
OM13006,598
Description
BOARD EVAL EM773 METER EU PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13006,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6681
NXP Semiconductors
UM10415
User manual
16.6.2.4 DeltaPhi1 calibration
16.6.2.5 DeltaPhi2 calibration
The calibration can be verified by checking the measured current I again. This should now
equal Iref2.
The phase error correction angle DeltaPhi1 can be calibrated as follows:
The calibration can be verified by measuring the fundamental reactive power Q1 for this
resistive load again. The fundamental reactive power Q1 should now be reduced towards
0 var for the resistive load.
The phase error correction angle DeltaPhi2 can be calibrated as follows:
The calibration can be verified by measuring the fundamental reactive power Q1 for this
resistive load again. The fundamental reactive power should now be reduced towards 0
var for the resistive load.
Connect an AC reference voltage source to the meter with the correct voltage and
frequency (e.g. 110V/60Hz or 230V/50Hz).
Set DeltaPhi1 to zero and apply a resistive load (that has no reactive power) to the
meter. Remark: Make sure the current is in the range for I1pp.
Measure the output values for fundamental Reactive Power Q1 and active power P.
The correction value DeltaPhi1 can then be calculated as:
Set this calculated value as DeltaPhi1.
Connect an AC reference voltage source to the meter with the correct voltage and
frequency (e.g. 110V/60Hz or 230V/50Hz).
Set DeltaPhi2 to zero and apply a resistive load (that has no reactive power) to the
meter. Remark: Make sure the current is in the range for I2pp.
Measure the output values for fundamental Reactive Power Q1 and active power P.
The correction value DeltaPhi2 can then be calculated as:
Set this calculated value as DeltaPhi2.
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 10 September 2010