PIC12C672T-10/SM Microchip Technology, PIC12C672T-10/SM Datasheet - Page 655

no-image

PIC12C672T-10/SM

Manufacturer Part Number
PIC12C672T-10/SM
Description
IC MCU OTP 2KX14 A/D 8-SOIJ
Manufacturer
Microchip Technology
Series
PIC® 12Cr
Datasheets

Specifications of PIC12C672T-10/SM

Core Processor
PIC
Core Size
8-Bit
Speed
10MHz
Peripherals
POR, WDT
Number Of I /o
5
Program Memory Size
3.5KB (2K x 14)
Program Memory Type
OTP
Ram Size
128 x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 4x8b
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
8-SOIC (5.3mm Width), 8-SOP, 8-SOEIAJ
For Use With
XLT08SO-1 - SOCKET TRANSITION 8SOIC 150/208AC164312 - MODULE SKT FOR PM3 16SOIC309-1048 - ADAPTER 8-SOIC TO 8-DIP309-1047 - ADAPTER 8-SOIC TO 8-DIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Connectivity
-
A.1
1997 Microchip Technology Inc.
Initiating and Terminating Data Transfer
During times of no data transfer (idle time), both the clock line (SCL) and the data line (SDA) are
pulled high through the external pull-up resistors. The START and STOP conditions determine
the start and stop of data transmission. The START condition is defined as a high to low transition
of the SDA when the SCL is high. The STOP condition is defined as a low to high transition of
the SDA when the SCL is high.
generates these conditions for starting and terminating data transfer. Due to the definition of the
START and STOP conditions, when data is being transmitted, the SDA line can only change state
when the SCL line is low.
Figure A-1:
Table A-1:
Transmitter
Receiver
Master
Slave
Multi-master
Arbitration
Synchronization
Term
Start and Stop Conditions
I
2
C Bus Terminology
The device that sends the data to the bus.
The device that receives the data from the bus.
The device which initiates the transfer, generates the clock and terminates
the transfer.
The device addressed by a master.
More than one master device in a system. These masters can attempt to
control the bus at the same time without corrupting the message.
Procedure that ensures that only one of the master devices will control the
bus. This ensure that the transfer data does not get corrupted.
Procedure where the clock signals of two or more devices are synchro-
nized.
SDA
SCL
Condition
Start
S
Figure A-1
Change
Allowed
of Data
shows the START and STOP conditions. The master
Description
Change
Allowed
of Data
Condition
Appendix A
Stop
P
DS31034A-page 34-3
34