LSISASX12 LSI, LSISASX12 Datasheet - Page 200

no-image

LSISASX12

Manufacturer Part Number
LSISASX12
Description
Manufacturer
LSI
Datasheet

Specifications of LSISASX12

Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LSISASX12A
Manufacturer:
LSILOGIC
Quantity:
5 510
Part Number:
LSISASX12A
Manufacturer:
LT
Quantity:
5 510
4-122
Register Descriptions
Copyright © 2004, 2005 by LSI Logic Corporation. All rights reserved.
Register FIS with Status[BSY]=0 and Error[ABRT] = 1
prior to transmitting a CLOSE sequence.
Unrecovered D2H Reg FIS
The LSISASx12 sets this read-only bit when the STP Tar-
get receives an R_ERR in response to a second attempt
to transmit a D2H Register FIS. If this occurs, the STP
Target transmits a CLOSE sequence to close the connec-
tion.
Unrecovered PIO Setup FIS
The LSISASx12 sets this read-only bit when the STP Tar-
get receives an R_ERR in response to a second attempt
to transmit a PIO Setup FIS. If this occurs, the STP Tar-
get transmits a CLOSE sequence to close the connec-
tion.
Unsupported FIS Received
The LSISASx12 sets this read-only bit when the STP Tar-
get receives one of the following FIS Types:
If the STP Target receives one of these FIS types, the
STP Target transmits an R_ERR, followed by a CLOSE
sequence to close the connection.
Payload/Transfer-Count Mismatch
The LSISASx12 sets this read-only bit when the number
of dwords received in a Host-to-Device DATA FIS does
not match the Transfer Count that was placed in the pre-
viously sent PIO Setup FIS. If this occurs, the Application
Layer notifies the Link Layer to send an R_ERR, and a
D2H Register FIS is transmitted to the host with a SCSI
Sense Key of ILLEGAL REQUEST (0x5) placed in the
Error register.
D2H Register FIS
DMA Activate FIS
DMA Setup FIS
PIO Setup FIS
Set Device Bits FIS
BIST Activate FIS