n25q064 Numonyx, n25q064 Datasheet - Page 44

no-image

n25q064

Manufacturer Part Number
n25q064
Description
64mb 1.8v, Multiple I/o, 4kb Subsector Erase, Xip Enabled, Serial Flash Memory With 108 Mhz Spi Bus Interface
Manufacturer
Numonyx
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
n25q064A11EF640E
Manufacturer:
MICRON/美光
Quantity:
20 000
Part Number:
n25q064A11EF640F
Manufacturer:
ST
0
Part Number:
n25q064A11ESE40F
Manufacturer:
NXP
Quantity:
25
Part Number:
n25q064A11ESE40F
Manufacturer:
MICRON
Quantity:
8 000
Part Number:
n25q064A11ESE40F
Manufacturer:
MICRON
Quantity:
20 000
Company:
Part Number:
n25q064A11ESE40F
Quantity:
62
Part Number:
n25q064A11ESEA0F
Manufacturer:
MICRON/美光
Quantity:
20 000
Company:
Part Number:
n25q064A11ESF40F
Quantity:
52
Part Number:
n25q064A13E1240E
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
n25q064A13E1240E
Manufacturer:
MICRON
Quantity:
20 000
Part Number:
n25q064A13E1240F
Manufacturer:
MICRON
Quantity:
1 200
Part Number:
n25q064A13E1240F
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
n25q064A13E1241E
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
n25q064A13E1241E
Manufacturer:
MICRON/镁光
Quantity:
20 000
Company:
Part Number:
n25q064A13E1241E
Quantity:
1 100
Protection modes
Table 9.
Table 10.
44/154
0
0
1
1
0
0
0
0
Lock Down
TB bit BP3 Bit BP2 Bit BP1 Bit BP0 Bit
Sector Lock Register
bit
0
0
0
0
Status Register Content
The Lock Registers can be read and written using the Read Lock Register (RDLR) and
Write to Lock Register (WRLR) instructions.
In each Lock Register two bits control the protection of each sector: the Write Lock bit and
the Lock Down bit.
The definition of the Lock Register bits is given in Table 9: Lock Register out.
SPM2
The second software protected mode (SPM2) uses the Block Protect bits (BP3, BP2, BP1,
BP0) and the Top/Bottom bit (TB bit) to allow part of the memory to be configured as read-
only. See
Software protection truth table (Sectors 0 to 127, 64 Kbyte granularity)
As a second level of protection, the Write Protect signal (applied on the W/VPP pin) can
freeze the Status Register in a read-only mode. In this mode, the Block Protect bits (BP3,
BP2, BP1, BP0) and the Status Register Write Disable bit (SRWD) are protected.
Protected area sizes (TB bit = 0)
0
1
0
1
Write Lock
0
0
0
0
bit
Write Lock bit: The Write Lock bit determines whether the contents of the sector can be
modified (using the Write, Program, or Erase instructions). When the Write Lock bit is
set to '1', the sector is write protected - any operations that attempt to change the data
in the sector will fail. When the Write Lock bit is reset to '0', the sector is not write
protected by the Lock Register, and may be modified.
Lock Down bit: The Lock Down bit provides a mechanism for protecting software data
from simple hacking and malicious attack. When the Lock Down bit is set to '1', further
modification to the Write Lock and Lock Down bits cannot be performed. A powerup is
required before changes to these bits can be made. When the Lock Down bit is reset to
'0', the Write Lock and Lock Down bits can be changed.
Section 16: Ordering
0
0
1
1
Sector unprotected from Program/Erase/Write operations, protection status reversible.
Sector protected from Program/Erase/Write operations, protection status reversible.
Sector unprotected from Program/Erase/Write operations.
Sector protection status cannot be changed except by a power-up.
Sector protected from Program/Erase/Write operations.
Sector protection status cannot be changed except by a power-up.
0
1
0
1
None
Upper 128th
Upper 64th
Upper 32nd
information.
Protected Area
Micron Technology, Inc., reserves the right to change products or specifications without notice.
Protection Status
Memory Content
All sectors
Sectors 0 to 126
Sectors 0 to 125
Sectors 0 to 123
©2010 Micron Technology, Inc. All rights reserved.
Unprotected Area
N25Q064 - 1.8V