XPSAF5130P SQUARE D, XPSAF5130P Datasheet - Page 101

SAFETY RELAY 300V 2.5A PREVENTA

XPSAF5130P

Manufacturer Part Number
XPSAF5130P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
Connections
Characteristics:
page 2/95
1 10/100BaseT 10/100BaseT 2
2/100
XPSMF3DIO8801
G
A2
L-
G
A1
L- L+ L+
24V DC
RUN
ERROR
PROG
FORCE
FAULT
OSL
BL
TO
LS+
DI
19 20 21 22
L-
1
1 2 4- 8-
1 2 3 4
2 3 4
B
E
23
5
6
DO-
24
S+
L-
DO
References:
page 2/97
L-
7
8 9 10
1 2 3 4+
C
11
12
L-
DO
LS+
DI
13
25 26 27 28
L-
14 15 16
5 6 7 8
5 6 7 8+
D
F
17
29
18
30
L-
L-
A1
A2
B
C
D
E
F
G
Item
Item
Connection
Supply
Ground
Outputs - Line control/
Digital
Outputs - Digital
Outputs - Digital
Inputs - Digital
Inputs - Digital
Connection
Programming
Safe Communication (all
XPSMF Safety PLCs and
Remote I/Os)
Safety automation system solutions
Preventa™ safety PLCs
Compact and modular
Safety remote mixed I/O modules XPSMF3
Dimensions, mounting:
page 2/98
Screw N° Screw
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Integrated 2 RJ45
switched Ethernet
Communication
ports
Integrated 2 RJ45
switched Ethernet
Communication
ports
Connections:
page 2/100
L-
L-
L+
L+
t
L-
1
2
4-
8-
S+
L-
1
2
3
4+
L-
L-
5
6
7
8+
L-
LS+
1
2
3
4
L-
LS+
5
6
7
8
L-
Function
c 24 V (reference pole)
c 24 V (reference pole)
c 24 V
c 24 V
Ground
Reference pole
Line control output 1
Line control output 2
Digital output 4- (for increased load)
Digital output 8- (for increased load)
Reference pole
Reference pole
Digital output 1
Digital output 2
Digital output 3
Digital output 4+ (for increased load)
Reference pole
Reference pole
Digital output 5
Digital output 6
Digital output 7
Digital output 8+ (for increased load)
Reference pole
Sensor supply for inputs 1 to 4
Digital input 1
Digital input 2
Digital input 3
Digital input 4
Reference pole
Sensor supply for inputs 5 to 8
Digital input 5
Digital input 6
Digital input 7
Digital input 8
Reference pole
Function
Either of the two switched Ethernet ports can be used
to create a connection between the safety remote I/O
and the programming terminal in a point to point or via
an Ethernet network for setting the IP address
Either of the two switched Ethernet ports can be
used to create a connection between the safety PLC
and other safety related components (e.g other
XPSMF safety PLCs or Safety Remote I/O modules)
this can be established in a point to point way or via
an Ethernet network.
Presentation
page 2/90

Related parts for XPSAF5130P