XPSAF5130P SQUARE D, XPSAF5130P Datasheet - Page 174

SAFETY RELAY 300V 2.5A PREVENTA

XPSAF5130P

Manufacturer Part Number
XPSAF5130P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
Electrical ratings
a.c. supply
d.c. supply
le: operational current measured.
Ue: operational voltage measured.
Cos
T0.95: time taken to reach 95% of nominal current.
AC-15
DC-13
le: operational current measured.
Ue: operational voltage measured.
Cos
T0.95: time taken to reach 95% of nominal current.
B300
C300
Type of current
Type of current
Electrical life
Definition of tests
Determination of electrical life conforming to EN 60947-5-1 (table C2)
Determination of the breaking capacity conforming to EN 60947-5-1 (table 4)
Utilization
category
Utilization
category
AC Voltage and Current Ratings 50-60 HZ
Contact Rating
Designation
j
j
: power factor.
: power factor.
(continued)
Utilization
category
AC-15
Utilization
category
DC-13
Start-up
Current
10 x le
Start-up
Current
le
5
2.5
Test Current, Amperes
Thermal Continuous
Voltage
Ue
Voltage
Ue
(continued)
Start-up
Current
10 x le
Start-up
Current
le
Cos
0.3
T0.95
50 ms
j
Maximum Current, Amperes
120 Volts
Make
30
15
Breaking
Current
le
Breaking
Current
le
Safety automation system solutions
Preventa™ safety relay modules
Notes:
The maximum values for the breaking capacity of the safety outputs in the various
Utilization categories are not fixed and depend on the power factor and on the
switching frequency. The test definition for the “breaking capacity” and “electrical life”
tables in the European standard EN 60947-5-1 uses different values for the power
factor and the switching frequency.
The power factor (cos j) in the “breaking capacity” table (0.3) is greater than that in
the “electrical life” table (0.7).
In the “breaking capacity” table, the switching frequency of the safety outputs is
higher for the first 1000 switching operations (60 per minute) than that for 1001 to
6050 switching operations (6 per minute).
Consequently, the maximum breaking capacity values determined using the
“breaking capacity” table are lower than those in the “electrical life” table.
Electrical life
The product life expressed is based on average usage and normal operating
conditions. The above statements are not intended to nor shall they create any
express or implied warranties as to product operation or life. For information on
the limited warranty offered on this product please refer to the Square D ® terms
and conditions of sale found in Square D ® Digest.
The tests are carried out with a frequency of 6 switching operations per minute and
with no additional protection of the components connected to the safety outputs.
The use of additional protection for the components connected to the safety outputs
significantly increases the durability of the safety outputs.
Voltage
Ue
Voltage
Ue
Voltage
Ue
Voltage
Ue
Break
3.00
1.50
Cos
0.3
T0.95
50 ms
j
Cos
0.7
T0.95
50 ms
Total number
of switching
operations
6050
Total number
of switching
operations
6050
240 Volts
Make
15
7.5
j
Breaking
Current
le
Breaking
Current
le
Switching
operations
per minute
for 1…1000
switching
operations
60
Switching
operations
per minute
for 1…1000
switching
operations
60
Break
1.5
0.75
Voltage
Ue
Voltage
Ue
Switching
operations
per minute
for 1001…6050
switching
operations
6
Switching
operations
per minute
for 1001…6050
switching
operations
6
Make
3600
1800
Volt amperes
Cos
0.4
T0.95
50 ms
Minimum
duration of
switching
operation
50 ms
Minimum
duration of
switching
operation
50 ms
Break
360
180
j
2/173
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9