XPSAF5130P SQUARE D, XPSAF5130P Datasheet - Page 5

SAFETY RELAY 300V 2.5A PREVENTA

XPSAF5130P

Manufacturer Part Number
XPSAF5130P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
Presentation
Presentation:
page 2/4
XPSMF4000
XPSMF4002
XPSMF4020
XPSMF4022
XPSMF4040
XPSMF4042
2/4
Characteristics:
page 2/10
References:
page 2/12
Safety automation system solutions
Preventa™ safety PLCs
Compact, XPSMF40
Preventa™ compact safety PLCs XPSMF40pp enable the monitoring of simple to
complex safety functions for all industrial applications relating to the protection of
personnel and machine safety.
Designed for use with numerous machine safety functions, these compact safety
PLCs are intended for use in safety related parts of control systems.
They can manage up to:
- category 4 conforming to EN 954-1,
- performance level “e” conforming to EN/ISO 13849-1,
- SIL 3 (safety integrity level) conforming to EN/IEC 61508.
The compact safety PLC range XPSMF40pp consists of 6 versions that are
differentiated by their non safety related communication protocols.
In order to meet safety requirements, the compact safety PLCs XPSMF40pp
incorporate two essential functions (Redundancy and Self-monitoring) complying
to category 4 conforming to EN 954-1 and performance level “e” conforming to
EN/ISO 13849-1 in addition to the SafeEthernet safety communication protocol
between the safety PLCs and the safety remote I/O modules (Special Switch).
b Redundancy: the triple processor integrated in the compact safety PLCs
analyzes and compares the data received from the safety inputs and outputs.
The incoming and outgoing data (programmed values and received values) are
received in parallel by the three processors and compared in real-time.
b Self-monitoring (“Watchdog”): the compact safety PLCs continuously monitor
the data processing cycle and the execution of tasks, and intervenes if the cycle time
does not conform to the predefined value.
b The integrated switch (Special Switch) stores for a very short time and sends at
very high speed the data provided by the inputs and outputs of the safety PLCs on
the Ethernet network, while avoiding signal collisions and excessive amounts of data
on the network.
Compact
PLCs
XPSMF4000 24, configurable 8
XPSMF4002 24, configurable 8
XPSMF4020 24, configurable 8
XPSMF4022 24, configurable 8
XPSMF4040 24, configurable 8
XPSMF4042 24, configurable 8
Presentation
Safety PLCs
Functional diagrams
Compact safety PLCs XPS4000/MF4002
12 digital I/O
12 digital I/O
4 line control
4 line control
channels
channels
(13…24)
(1…12)
outputs
outputs
(1…4)
(5…8)
Digital
Inputs/Outputs
“Watchdog”
processor
system
Triple
Dimensions, mounting:
page 2/15
Line
control
outputs
Communication
On Ethernet network
Safety
protocol
SafeEthernet –
SafeEthernet Modbus® TCP/IP
SafeEthernet –
SafeEthernet Modbus® TCP/IP
SafeEthernet –
SafeEthernet Modbus® TCP/IP
dual port
RAM
Non safety
protocol
Server
Server
Server
Connections:
page 2/16
Integrated
switch
COM
On fieldbus
Modbus® serial
Slave (RTU)
Modbus® serial
Slave (RTU)
PROFIBUS DP
V0 slave
PROFIBUS DP
V0 slave
RJ45
RJ45

Related parts for XPSAF5130P