XPSAF5130P SQUARE D, XPSAF5130P Datasheet - Page 80

SAFETY RELAY 300V 2.5A PREVENTA

XPSAF5130P

Manufacturer Part Number
XPSAF5130P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
Dimensions,
connections
(1) Removable screw terminals are provided with safety input module XPSMF1DI1601.
Dimensions
XPSMF1DI1601
Connections
XPSMF1DI1601
1 10/100BaseT 10/100BaseT 2
.51
13
G
(1)
(1)
A2
L-
G
A1
L- L+ L+
2.44
24V DC
RUN
ERROR
PROG
FORCE
FAULT
OSL
BL
62
2.62
66.5
DI
DI
LS+
LS+
19 20 21 22
1
13 14 15 16
1 2 3 4
2 3 4
B
E
.06
23
1.5
5
4.45
6
24
L-
L-
113
DI
LS+
7
8 9 10
5 6 7 8
C
11
12
L-
DI
.06
LS+
L-
TO
13
1.5
25 26 27 28
14 15 16
9 10 11 12
1 2 3 4
D
F
17
29
18
30
L-
L-
A1
A2
B
C
D
E
F
G
Item
Item
5.98
152
Safety automation system solutions
Preventa™ safety PLCs
Compact and modular
Safety remote input modules XPSMF1
Connection
Supply
Ground
Digital inputs
Digital inputs
Digital inputs
Digital inputs
Line control outputs
Connection
Programming
Safe Communication
(all XPSMF Safety
PLCs and Remote I/Os)
.06
1.5
4.29
109
Screw N° Screw Function
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Type
Integrated 2
RJ45 switched
Ethernet
Communication
ports
Integrated 2
RJ45 switched
Ethernet
Communication
ports
L+
L+
L-
L-
t
LS+
1
2
3
4
L-
LS+
5
6
7
8
L-
LS+
9
10
11
12
L-
LS+
13
14
15
16
L-
L+
1
2
3
4
L-
RJ45 connector for access to Ethernet network
(SafeEthernet protocol)
c 24 V
c 24 V
c 24 V (reference pole)
c 24 V (reference pole)
Ground
Sensor supply for inputs 1 to 4
Digital input 1
Digital input 2
Digital input 3
Digital input 4
Reference pole
Sensor supply for inputs 5 to 8
Digital input 5
Digital input 6
Digital input 7
Digital input 8
Reference pole
Sensor supply for inputs 9 to 12
Digital input 9
Digital input 10
Digital input 11
Digital input 12
Reference pole
Sensor supply for inputs 13 to 16
Digital input 13
Digital input 14
Digital input 15
Digital input 16
Reference pole
Outputs common
Output 1
Output 2
Output 3
Output 4
Outputs common
Function
Either of the two switched Ethernet ports can be used to
create a connection between the safety remote I/O and
the programming terminal in a point to point or via an
Ethernet network for setting the IP address
Either of the two switched Ethernet ports can be used
to create a connection between the safety PLC and
other safety related components (e.g other XPSMF
safety PLCs or Safety Remote I/O modules) this can be
established in a point to point way or via an Ethernet
network.
r .89
22.5
min.
Dual Dimensions:
INCHES
Millimieters
2/79
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9

Related parts for XPSAF5130P