XPSAF5130P SQUARE D, XPSAF5130P Datasheet - Page 121

SAFETY RELAY 300V 2.5A PREVENTA

XPSAF5130P

Manufacturer Part Number
XPSAF5130P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
Presentation
Premium™ automation
platform
Presentation:
page 2/118
2/120
Premium™ automation platform
ATV 71
Premium™ automation platform
TeSys U
CANopen bus
Configurable controller
XPSMC16ZP, MC32ZP
Configurable controllers XPSMC16Zp/MC32Zp,
Characteristics:
page 2/122
Micro automation platform
slaves of the Modbus® serial link
Modbus® serial link
Advantys STB
TeSys Quickfit
Profibus bus
Third-party
Magelis® graphic terminal
products
Safety automation system solutions
Preventa™ configurable safety controllers
type XPSMC
References:
page 2/124
Configurable
controllers
XPSMC16ZC,
MC32ZC
FTB 1CN
Repeater
(3 max.)
Configurable safety controllers XPSMCppZC incorporate a
SUB-D 9-pin male connector for direct connection on
CANopen bus.
CANopen bus is an open bus that ensures deterministic and
reliable access to the real-time data of automation equipment.
The bus uses a shielded dual twisted pair on which a
maximum of 127 devices can be connected by chaining.
The data rate varies between 10 Kbps and 1Mbps depending
on the length of the bus (16,404 to 66 ft / 5,000 to 20 m).
Configurable safety controllers XPSMCppZP incorporate a
SUB-D 9-pin female connector for connection on Profibus
bus.
Configurable safety controllers XPSMCppZP are slaves on
the Profibus bus.
Profibus bus is a fieldbus that meets industrial communication
requirements. The topology of the Profibus bus is of the linear
type with a centralised master/slave type access procedure.
The physical link is a single shielded twisted pair.
Configurable safety controllers XPSMCppZp MC incorporate
a Modbus® communication interface (RJ45 connector) for
configuration and diagnostics.
This interface enables connection of the controllers to:
v a PC (configuration),
v a PLC (diagnostics), or
v an operator dialog terminal (diagnostics).
The Modbus® serial link consists of a master station
(Premium™ automation platform) and slave stations
(configurable controllers XPSMC16/32Zp).
Two exchange mechanisms are possible:
b Question/response: the questions from the master are
addressed to a given slave. The response is expected by
return from the interrogated slave.
b Distribution: the master distributes a message to all the
stations of the Modbus® serial link. The latter execute the
order without transmitting a reply.
Communication
CANopen fieldbus
Profibus bus
Modbus® serial link
Dimensions:
page 2/125
Wiring Diagrams:
page 2/126
0

Related parts for XPSAF5130P