XPSAF5130P SQUARE D, XPSAF5130P Datasheet - Page 38

SAFETY RELAY 300V 2.5A PREVENTA

XPSAF5130P

Manufacturer Part Number
XPSAF5130P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
Presentation
XPSMFCIO2401
XPSMFAO801
XPSMFDO801
XPSMFDIO241601
Safety automation system solutions
Preventa™ safety PLCs
Modular, XPSMF60
Rack, power supply and CPU
In addition to the inputs/outputs available as standard on the optional “in rack” cards,
the modular safety PLC XPSMF60 can be connected to safety remote input modules
XPSMF1 and/or safety remote output modules XPSMF2 and/or safety remote mixed
I/O modules XPSMF3.
The safety remote input, output and mixed I/O modules can be located within the
vicinity of the machines to be monitored, thus reducing cabling.
Communication between these safety modules and the safety PLC XPSMF60 is
performed on an Ethernet network using the SafeEthernet safety protocol, via the
integrated RJ45 switched Ethernet communications ports.
(1) Removable screw terminal blocks are provided with the power supply and “in rack” I/O cards.
(2) Use shielded dual twisted pair cables, maximum length 984 ft (300 m), short-circuit unused
analog inputs.
XPSMFCIO2401 2
XPSMFDIO241601 24
XPSMFAO801
XPSMFDO801
Safety inputs and outputs
Mixed I/O cards
Card
Card
Analog output card
Card
Relay output card
Card
Remote inputs and outputs
Counting inputs
(1)
Digital inputs
Analog outputs
8
Relay outputs
8
(1) (2)
c 5 V
Incremental
encoders
Independent and configurable
counting inputs (one channel for
counting and one channel for
increasing or decreasing
counting direction)
(1) (2)
Type
Safety detection
Limit switches,
Guard switches, with reset and
with actuator,
Light curtains type 2 and type 4,
Safety mats and sensing
edges…
Safety dialog
Mushroom head Emergency
stops,
Enclosures for control and
signalling units,
Two-hand control stations…
Functions
Closed circuit scanning of output channels,
Single-pole measuring of 0 to 10 V voltages,
Measuring, using jumper, 0/4 to 20 mA currents (with 500 W external
resistor)
Type
Safety actuators
Contactors-motors,
Control relays,
Variable speed drives.
Safety dialog
Beacons and indicator banks,
Rotating mirror beacons, Sirens…
(continued)
c 24 V
Sensors
2/3-wire
PNP/NPN
Digital outputs
4
Digital outputs
16
Type
Safety actuators
Contactors-motors,
Control relays,
Variable speed drives.
Safety dialog
Beacons and indicator banks,
Rotating mirror beacons,
Sirens…
Type
Safety actuators
Contactors-motors,
Control relays,
Variable speed drives.
Safety dialog
Beacons and indicator
banks,
Rotating mirror beacons,
Sirens…
2/37
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9