XPSAF5130P SQUARE D, XPSAF5130P Datasheet - Page 175

SAFETY RELAY 300V 2.5A PREVENTA

XPSAF5130P

Manufacturer Part Number
XPSAF5130P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
Operating principle,
characteristics
Product designed for max. use in safety related parts of
control systems (conforming to EN 954-1/ISO 13849-1)
Conformity to standards
Product certifications
Supply
Power consumption
Start button monitoring
Control unit voltage
(at nominal supply
voltage)
Outputs
Electrical life
Response time on input opening
Rated insulation voltage (Ui)
Rated impulse withstand voltage (Uimp.)
LED display
Operating temperature
Storage temperature
Degree of protection
conforming to EN/IEC
60529
Principle:
page 2/174
2/174
Operating principle
Characteristics
Module type
Voltage
Voltage limits
Frequency
24 V version
48 V version
115 V version
230 V version
Voltage reference
Number and type of safety circuits
Number and type of additional circuits
Breaking capacity in AC-15
Breaking capacity in DC-13
Max. thermal current (Ithe)
Max. total thermal current
Output fuse protection, using fuses
conforming to EN/IEC 60947-5-1,
DIN VDE 0660 part 200
Minimum current
Minimum voltage
Terminals
Enclosure
Characteristics:
page 2/174
Safety automation system solutions
Preventa™ safety relay modules type XPSAC
For Emergency stop and switch monitoring
Safety modules XPSAC are used for monitoring Emergency stop circuits conforming
to standards EN/ISO 13850 and EN 60204-1 and also meet the safety requirements
for the electrical monitoring of switches in protection devices conforming to standard
EN 1088/ISO 14119. They provide protection for both the machine operator and the
machine by immediately stopping the hazardous movement on receipt of a stop
instruction from the operator, or on detection of an anomaly in the safety circuit itself.
To aid diagnostics, the modules have LEDs which provide information on the
monitoring circuit status.
The XPSAC module has 3 safety outputs and a solid-state output for signalling to the
PLC.
References:
2/175
V
Hz
W
VA
V
V
V
V
VA
A
A
A
mA
V
ms
V
kV
°F (°C) + 14…+ 131 (- 10…+ 55)
°F (°C) - 13…+ 267.8 (- 25…+ 85)
XPSAC
Category 3 max.
EN 60204-1, EN 1088/ISO 14119, EN/ISO 13850, EN/IEC 60947-1 + A11,
EN/IEC 60947-5-1
UL, CSA, BG
a and c 24, a 48, a 115, a 230
- 20…+ 10% (a 24 V)
- 20…+ 20% (c 24 V)
- 15…+ 10% (a 48)
- 15…+ 15% (115 V)
- 15…+10% (230 V)
50/60
< 1.2 (c 24 V)
< 2.5 (a 24 V)
< 6 (a 48 V)
< 7 (a 115 V)
< 6 (a 230 V)
No
Identical to supply voltage
a 24 (approx. 90 mA), c 24 (approx. 40 mA)
a 48 (approx. 100 mA)
a 115 (approx. 60 mA)
a 230 (approx. 25 mA)
Relay hard contacts
3 N.O. (13-14, 23-24, 33-34)
1 solid-state
C300: inrush 1800, maintained 180
24 V/2 A L/R = 50 ms
6
10.5
4 gG (gl) or 6 fast acting
10
17
See page 2/172
< 100
300 (degree of pollution 2 conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2)
3 (overvoltage category III, conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2)
2
IP 20
IP 40
Wiring Diagrams:
page 2/176
XPSACppppP
Dimensions:
page 2/260
0