Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
Characteristics
Product designed for max. use in safety related parts of
control systems (conforming to EN 954-1/ISO 13849-1)
Conformity to standards
Product certifications
Supply
Power consumption
Module inputs fuse protection
Inputs
Two-hand control type
Conforming to EN 574/ISO 13851
Synchronization time
Control unit
voltage
Minimum voltage and current
Calculation of wiring resistance RL (for XPSBC only)
between terminals T11-T13, T21-T23 as a function of the internal
supply voltage U int (terminals T13-T23)
Outputs
Electrical life
Response time
Rated insulation voltage (Ui)
Rated impulse withstand voltage (Uimp.)
LED display
Operating temperature
Storage temperature
Degree of protection
conforming to IEC/EN 60529
Connections
Principle:
page 2/206
Characteristics
Module type
Voltage
Voltage limits
Frequency
c 24 V version
a 24 V, 115 V, 230 V version
U min./I min. - c 24 V version 68 °F (20 °C)
U min./I min. - a 24 V/115 V/230 V version
68 °F (20 °C)
Voltage reference
Number and type of safety circuits
Number and type of additional circuits
Breaking capacity in AC-15
Breaking capacity in DC-13
Max. thermal current (Ithe)
Output fuse protection, using fuses
conforming to EN/IEC 60947-5-1,
VDE 0660 part 200
Minimum current
Minimum voltage
1-wire connection
2-wire connection
Characteristics:
page 2/207
Terminals
Enclosure
Type
Without cable end
With cable end
With cable end
Without cable end
With cable end
With cable end
Safety automation system solutions
Preventa™ safety relay modules types
XPSBA, XPSBC
For electrical monitoring of two-hand control stations
References:
page 2/209
V
Hz
VA
s
V
V
W
VA
A
A
mA
V
ms
V
kV
°F (°C) + 14…+ 131 (- 10…+ 55)
°F (°C) - 13…+ 267.8 (- 25…+ 85)
XPSBA
Category 1 max.
EN/IEC 60204-1, EN/IEC 60947-5-1,
EN 574/ISO 13851 type III A, EN 50082-2
UL, CSA
z 24, a 115, a 230
- 20…+ 20% (c 24 V),
- 20…+ 10% (a 24 V),
- 15…+ 15% (a 115 V),
- 15…+ 10% (a 230 V)
50/60
< 20 (apparent power)
Internal, electronic
S1: 1 N.C. + N.O., S2: 1 N.C. + N.O.
III A
0.5 maximum
24
24
Between terminals T11-T12, T11-T13
18 V/30 mA
18 V/30 mA
Relay hard contacts
1 N.O. (11-14)
1 N.C. (11-12)
C300: inrush 1800, maintained 180
24 V/1.5 A - L/R = 50 ms
5
4 gG or 6 fast acting
10
17
See page 2/172
< 25
300 (degree of pollution 2 conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2)
4 (overvoltage category III, conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2)
2
IP 20
IP 40
Captive screw clamp terminals
Solid or flexible cable: 26-14 AWG (0.14…2.5 mm
Without bezel, flexible cable: 24-14 AWG (0.25…2.5 mm
With bezel, flexible cable: 24-16 AWG (0.25…1.5 mm
Solid or flexible cable: 26-18 AWG (0.14…0.75 mm
Without bezel, flexible cable: 24-18 AWG (0.25…1 mm
Double, with bezel, flexible cable: 20-16 AWG (0.5…1.5 mm
Wiring Diagrams:
page 2/210
4 gG
XPSBC
Category 4 max.
EN/IEC 60204-1, EN/IEC 60947-5-1,
EN 574 type III C/ISO 13851, EN 50082-2
UL, CSA, INRS
c 24, a 24, a 115, a 230
- 20…+ 10% (c 24 V),
- 15…+ 10% (a 24 V),
- 15…+ 15% (a 115 V),
- 15…+ 10% (a 230 V)
< 6
III C
24
48
Between terminals T11-T13, T21-T23
18 V/140 mA
30 V/50 mA
RL max. =
Ue = true voltage applied to terminals
A1-A2
U int = supply voltage Ue -1 V (24 V
version)
(115 V, 230 V version) RL max. must not
exceed 50 W
U int between 30.5 V and 35 V, with typical
value = 35 V
2 N.O. (13-14, 23-24)
1 N.C. (31-32)
2.5
< 30
3
2
)
2
)
2
)
2
)
2
U int - U min.
Dimensions:
page 2/260
)
2
I min.
)
2/207
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9