XPSAF5130P SQUARE D, XPSAF5130P Datasheet - Page 34

SAFETY RELAY 300V 2.5A PREVENTA

XPSAF5130P

Manufacturer Part Number
XPSAF5130P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
Connections (continued)
A1
A2
B
C
D
E
Connections
XPSMF35pp
Item
Connection
Supply
Ground
Outputs - Digital
Inputs - Digital
Inputs - Digital
Inputs - Digital
Screw
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Screw Function
L+
L+
L-
L-
t
L-
1
2
3
4
5
6
7
8
L-
LS+
1
2
3
4
5
6
7
8
L-
LS+
9
10
11
12
13
14
15
16
L-
LS+
17
18
19
20
21
22
23
24
L-
c 24 V
c 24 V
c 24 V (reference pole)
c 24 V (reference pole)
Ground
Outputs common
Digital output 1
Digital output 2
Digital output 3
Digital output 4 (for increased load)
Digital output 5
Digital output 6
Digital output 7
Digital output 8 (for increased load)
Outputs common
Sensor supply for inputs 1 to 8
Digital input 1
Digital input 2
Digital input 3
Digital input 4
Digital input 5
Digital input 6
Digital input 7
Digital input 8
Inputs common
Sensor supply for inputs 9 to 16
Digital input 9
Digital input 10
Digital input 11
Digital input 12
Digital input 13
Digital input 14
Digital input 15
Digital input 16
Inputs common
Sensor supply for inputs 17 to 24
Digital input 17
Digital input 18
Digital input 19
Digital input 20
Digital input 21
Digital input 22
Digital input 23
Digital input 24
Inputs common
Safety automation system solutions
Preventa™ safety PLCs
Compact, XPSMF31/30/35
F
G
H
I
J
K
L
Item
(cont.)
Item
Connection
Inputs - Analog
Inputs - Analog
Inputs - Analog
Inputs - Analog
Inputs - Counter
Connection
Communication
Programming
Safe Communication
(all XPSMF Safety
PLCs and Remote
I/Os)
Non-Safe
Communication
available with
references:
XPSMF3502,
XPSMF3522 and
XPSMF3542
Screw N° Screw Function
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
Type
SUB-D 9-pin
(FB3)
Integrated 4 RJ45
switched Ethernet
Communication
ports
T1
I1
L-
T2
I2
L-
T3
I3
L-
T4
I4
L-
T5
I5
L-
T6
I6
L-
T7
I7
L-
T8
I8
L-
A1
B1
Z1
L-
A2
B2
Z2
L-
Transmitter supply 1
Analog input 1
Inputs common
Transmitter supply 2
Analog input 2
Inputs common
Transmitter supply 3
Analog input 3
Inputs common
Transmitter supply 4
Analog input 4
Inputs common
Transmitter supply 5
Analog input 5
Inputs common
Transmitter supply 6
Analog input 6
Inputs common
Transmitter supply 7
Analog input 7
Inputs common
Transmitter supply 8
Analog input 8
Inputs common
Input A1 or bit 0 (LSB)
Input B1 or bit 1
Input Z1 or bit 2 (MSB)
Inputs common
Input A2 or bit 0 (LSB)
Input B2 or bit 1
Input Z2 or bit 2 (MSB)
Inputs common
Function
XPS3522: slave on Modbus®
serial (RTU)
XPS3542: slave V0 on
PROFIBUS DP
Either of the four switched
Ethernet ports can be used to
create a connection between
the safety PLC and the
programming terminal in a
point to point or via an
Ethernet network for
programming, setting IP
address etc.
Either of the four switched
Ethernet ports can be used to
create a connection between
the safety PLC and other safety
related components (e.g other
XPSMF safety PLCs or Safety
Remote I/O modules) this can
be established in a point to
point way or via an Ethernet
network.
Either of the four switched
Ethernet ports can be used to
create a connection between
the safety PLC and other
non- safety related
components (e.g HMI Magelis
®, standard PLCs, Scada
systems,etc.) this can be
established in a point to point
way or via an Ethernet
network.
2/33
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9

Related parts for XPSAF5130P