XPSAF5130P SQUARE D, XPSAF5130P Datasheet - Page 23

SAFETY RELAY 300V 2.5A PREVENTA

XPSAF5130P

Manufacturer Part Number
XPSAF5130P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
Description
10
12
10
Presentation:
page 2/18
13
11
9
5
8
7
6
5
9
2/22
9
8
1
1
4
7
2
2
3
Characteristics:
page 2/24
3
4
5
6
References:
page 2/27
Safety automation system solutions
Preventa™ safety PLCs
Compact, XPSMF31/30/35
On the front cover of the metal enclosure:
1 One terminal block (1) for c 24 V supply.
2 Two terminal blocks (1) for connection of digital outputs, with output status LED
3 Five terminal blocks (1) for connection of digital inputs, with input status LED (four
4 Eight process status LEDs.
5 Four integrated RJ45 (type 10BASE-T/100BASE-TX) switched ports for
6 On XPSMF3022 only: two unused SUB-D connectors (FB1 and FB2).
7 On XPSMF3022 only: one SUB-D 9-pin connector for connection on Modbus®
8 One ground connection screw.
9 On the top: one “Reset” button.
10 On the rear face: one spring operated mounting device for mounting on 35 mm 5
On the front cover of the metal enclosure:
1 One terminal block (1) for c 24 V supply.
2 One terminal block (1) for connection of digital outputs, with four digital output
3 Three terminal blocks (1) for connection of digital inputs, with input status LED
4 One terminal block (1) for connection of 2 counting input channels.
5 Four terminal blocks (1) for connection of analog inputs.
6 One plate for securing shielded analog input connection cables.
7 Eight process status LEDs.
8 Two unused SUB-D connectors (FB1 and FB2).
9 Four integrated RJ45 (type 10BASE-T/100BASE-TX) switched ports for
10 One type SUB-D 9-pin connector (FB3) for connection on PROFIBUS DP
11 One ground connection screw.
12 On the top: one “Reset” button.
13 On the rear face: one spring operated mounting device for mounting on 35 mm 5
(1) Removable screw terminals are provided with compact safety PLCs XPSMF31/30/35.
Description
Safety PLCs XPSMF31222 and XPSMF3022
Safety PLCs XPSMF35pp
(four LEDs per terminal block).
LEDs per terminal block).
programming, and for Safety and non-safety related communication on Ethernet
(safety related using SafeEthernet protocol and Non-safety related using
Modbus® TCP/IP server protocol).
serial (RTU) (FB3).
rail.
status LEDs.
(eight LEDs per terminal block).
programming, and for Safety and non-safety related communication on Ethernet
(safety related using SafeEthernet protocol and Non-safety related using
Modbus® TCP/IP server protocol).
(XPSMF3542) or Modbus® serial (RTU) (XPSMF3522).
rail.
Dimensions, mounting:
page 2/30
Connections:
page 2/32

Related parts for XPSAF5130P