XPSAF5130P SQUARE D, XPSAF5130P Datasheet - Page 247

SAFETY RELAY 300V 2.5A PREVENTA

XPSAF5130P

Manufacturer Part Number
XPSAF5130P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
10
1
2
3
4
5
6
7
8
9
Operating principle,
characteristics
Product designed for max. use in safety related parts of
control systems (conforming to EN 954-1/ISO 13849-1)
Conformity to standards
Product certifications
Supply
Maximum power
consumption
Module inputs fuse protection
Control unit voltage between S11-S12, S21-S22
Protection of the control unit contacts
Minimum voltage and
current between terminals
S11-S12, S21-S22 (inputs
A and B)
Calculation of wiring resistance RL
between terminals S11-S12, S21-S22 as a function of the internal
supply voltage U int (terminals S11-S21)
Synchronization time between inputs A and B,
automatic start, linked terminals S33-S34 and Y3-Y4
Outputs
Electrical life
Response time on input opening
Rated insulation voltage (Ui)
Rated impulse withstand voltage (Uimp.)
LED display
Operating temperature
Storage temperature
Degree of protection conforming to IEC 60529
Connection
Door
unlocking
zone
Characteristics
Module type
2/246
Operating principle
Landing indicator
(stop reference point)
Voltage
Voltage limits
Frequency
24 V
115 V/230 V
U min./I min. - 24 V version
68 °F (20 °C)
U min./I min. - 115 V/230 V version
68 °F (20 °C)
Voltage reference
Number and type of safety circuits
No. and type of additional circuits
Breaking capacity in AC-15
Breaking capacity in DC-13
Breaking capacity of solid-state
outputs
Max. thermal current (Ithe)
Output fuse protection
Minimum current (relay hard contact) mA
Minimum voltage (relay hard contact) V
Max. total thermal current
Type
Cabin doors
+ 7.87 in (200 mm)
- 7.87 in (200 mm)
Cabin
Landing
Landing
doors
Safety automation system solutions
Preventa™ safety relay modules type XPSDA
For elevator control
When the cabin is parked at a landing, with the doors open, some elevators
automatically correct their level (isolevelling) in relation to the landing in order to
compensate for any differences generated by changes in the load in the cabin.
During this operation, European standard EN-81 recommends that the presence of
the cabin be checked within a zone of +/- 7.87 in (200 mm) around the landing (door
unlocking zone), by means of a safety circuit which will cause the cabin to stop if it
moves out of the specified zone.
The use of a safety module XPSDA, which checks the presence of the cabin in the
specified zone at two points, meets this requirement.
The module incorporates two safety outputs and two solid-state outputs for signalling
functions. Four LEDs on the front cover of the module provide visual indication of
the status of the safety circuit.
The position of the cabin in relation to the landing is detected by two limit switches in
the elevator shaft. It is also possible to use non-contact sensors (magnetic sensors
with reed contact).
When the cabin reaches the preset position and when it is within the permissible
tolerances in relation to the landing, the two safety circuits in safety module XPSDA
close and allow isolevelling of the cabin with the doors open. Any change in one of
the input signals (cabin outside the specified zone) or detection of an anomaly (break
in the wiring, short-circuit, etc.) causes immediate opening of the safety outputs in
the XPSDA module and subsequent stopping of the cabin.
V
Hz
VA
VA
V
W
ms
VA
A
ms
V
kV
°F (°C) + 14 …+ 149 (- 10…+ 65)
°F (°C) - 13…+ 185 (- 25…+ 85)
XPSDA
Category 4 max.
EN 81-1, EN 81-2, EN/IEC 60947-5-1, EN 50082-2, EN 12015, EN 12016
UL, CSA, TÜV
a and c 24, a 115, a 230
- 20…+ 10% (a 24 V), - 20…+ 20% (c 24 V), - 15…+ 15% (a 115 V),
- 15…+ 10% (a 230 V)
50/60
< 9
< 10
Internal, electronic
24 (24 V version), 48 (115 V, 230 V versions)
By limitation of the maximum current in the event of short-circuit (< 185 mA)
16 V/70 mA
41 V/25 mA
Approx. 300
Relay hard contacts
2 N.O. (13-14, 23-24)
2 solid-state
C300: inrush 1800, maintained 180
24 V/1.5 A - L/R = 50 ms
24 V/20 mA
2.5
6 A fast acting, 4 gG, conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
10
17
5
See page 2/172
< 40
300 (degree of pollution 2 conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2)
4 (overvoltage category III, conforming to EN/IEC 60947-1, DIN VDE 0110 parts 1 & 2)
4
Terminals: IP 20. Enclosure: IP 50
Captive screw clamp terminals: without cable end 1 x 12 AWG (1 x 4 mm
end 2 x 14 AWG (2 x 2.5 mm
RL max. =
U int - U min.
I min.
2
)
Ue = true voltage applied to terminals A1-A2
U int = supply voltage Ue - 3 V (24 V version)
U int between 42 V and 45 V,
with typical value = 45 V (115 V, 230 V version)
RL max. must not exceed 50 W
2
), with cable
0

Related parts for XPSAF5130P