XPSAF5130P SQUARE D, XPSAF5130P Datasheet - Page 213

SAFETY RELAY 300V 2.5A PREVENTA

XPSAF5130P

Manufacturer Part Number
XPSAF5130P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
Wiring diagrams
L1 (
S1
Principle:
page 2/206
L1 (
N (
N (
2/212
XPSBC
Module XPSBC associated with a two-hand control station and a foot switch
Modules XPSBC associated with 2 two-hand control stations
S4
-
-
+
+
)
)
)
)
F1
F1
123
012
XPS BC
A1
A2
T11
S3
XPS BC
XPS BC
K3
K4
A1
A2
A1
A2
Y1
K3
S1
T11
T11
Characteristics:
page 2/207
Y1
Y1
T13
S11
1
S21
1
Y2
(continued)
T13
T13
2
2
T12
K4
T12
Y2
T12
Y2
3
3
T21
T21
T21
4
4
S12
S22
T23
T23
S2
5
5
T23
T22
T22
6
6
K3
Safety automation system solutions
Preventa™ safety relay modules type XPSBC
For electrical monitoring of two-hand control stations
7
8
References:
page 2/209
T22
13
14
13
14
K3
8
13
14
7
X1
X2
K4
K4
23
24
9
10
23
24
23
24
31
32
10
9
31
32
31
32
S4 selector switch:
0 = stop
1 = control station
2 = foot switch
S1-S2: two-hand control station pushbuttons
S3: foot switch
When operator 1 is absent: replace terminal block X1 by X3 and
physically remove the two-hand control station.
When operator 2 is absent: replace terminal block X2 by X3 and
physically remove the two-hand control station.
S1 selector switch:
1 = operator 1
2 = operator 2
3 = operator 1 and operator 2
S11-S12, S21-S22: two-hand control station pushbuttons
X3
Wiring Diagrams:
page 2/210
1
2
3
4
5
6
7
8
Dimensions:
page 2/260
9
10

Related parts for XPSAF5130P