XPSAF5130P SQUARE D, XPSAF5130P Datasheet - Page 207

SAFETY RELAY 300V 2.5A PREVENTA

XPSAF5130P

Manufacturer Part Number
XPSAF5130P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
Operating principle
Principle:
page 2/206
2/206
Characteristics:
page 2/207
Safety automation system solutions
Preventa™ safety relay modules types XPSBA,
XPSBC, XPSBF
For electrical monitoring of two-hand control stations
Two-hand control stations are designed to provide protection against hand injury.
They require machine operators to keep their hands clear of the hazardous
movement zone.
The use of two-hand control is an individual protective measure, which can safely
protect only one operator. Separate two-hand control stations must be provided for
each operator in a multiple-worker environment.
Safety modules XPSBA, BC and BF for two-hand control stations comply with the
requirements of European standard EN 574/ISO 13851 for two-hand control
systems.
The control stations must be designed and installed such that they cannot be
activated involuntarily or easily rendered inoperative. Depending on the application,
the requirements of type C standards specific to the machinery involved must be met
(additional personal protection methods may have to be considered).
To initiate a hazardous movement, both operators (two-hand control pushbuttons)
must be activated within an interval y 0.5 s (synchronous activation). If one of the two
pushbuttons is released during a hazardous operation, the control sequence is
cancelled. Resumption of the hazardous operation is possible only if both
pushbuttons are returned to their initial position and reactivated within the required
time interval.
• Both two-hand control push buttons are pressed during a time period greater than
0.5 seconds,
• A short-circuit is present in a push button contact,
• The feedback loop is not closed at start-up.
The safety distance between the control units and the hazardous zone must be
sufficient to ensure that when only one operator is released, the hazardous zone
cannot be reached before the hazardous movement has been completed or stopped.
This module is designed for use on lighter duty applications where a two-hand
control function is desired, but where the safety category is B or 1 (per EN 954-1)
and the two-hand control requirements meet Type III A (per EN 574). This module is
not to be used for applications, such as presses, which require a Type III C
module or where the application is not a category B or 1. For press applications,
for applications in category 2, 3, or 4, or if application calls for a Type III C module,
use XPSBC or XPSBF module.
These modules can be used on applications, such as presses, which require a Type
III C module. The XPSBC and XPSBF can be used for a two-hand control
application, including presses and similar equipment.
References:
page 2/209
Operating principle
The control sequence does not occur if:
XPSBA
XPSBC and XPSBF
Wiring Diagrams:
page 2/210
Dimensions:
page 2/260