XPSAF5130P SQUARE D, XPSAF5130P Datasheet - Page 33

SAFETY RELAY 300V 2.5A PREVENTA

XPSAF5130P

Manufacturer Part Number
XPSAF5130P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
Connections
A1
A2
B
C
D
E
F
Characteristics:
page 2/24
Connections
XPSMF31222, XPSMF3022
Item
Connection examples
Actuator connections to the outputs
2/32
Connection
Supply
Ground
Outputs
Digital
Outputs
Digital
Inputs
Digital
Inputs
Digital
Inputs
Digital
Screw
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Screw Function
L+
L+
L-
L-
t
L-
1
2
3
4
L-
L-
5
6
7
8
L-
LS+
1
2
3
4
L-
LS+
5
6
7
8
L-
LS+
9
10
11
12
L-
References:
page 2/27
c 24 V
c 24 V
c 24 V (reference pole)
c 24 V (reference pole)
Ground
Outputs common
Output 1
Output 2
Output 3
Output 4 (for increased load)
Outputs common
Outputs common
Output 5
Output 6
Output 7
Output 8 (for increased load)
Outputs common
Sensor supply for inputs 1 to 4
Digital input 1
Digital input 2
Digital input 3
Digital input 4
Inputs common
Sensor supply for inputs 5 to 8
Digital input 5
Digital input 6
Digital input 7
Digital input 8
Inputs common
Sensor supply for inputs 9 to 12
Digital input 9
Digital input 10
Digital input 11
Digital input 12
Inputs common
Dimensions, mounting:
page 2/30
Safety automation system solutions
Preventa™ safety PLCs
Compact, XPSMF31/30/35
OFF 1
G
H
K
J
Emergency stop connections (line control)
Item
Item
Connection
Inputs
Digital
Inputs
Digital
Connection
Communication
Programming
Safe
Communication
(all XPSMF
Safety PLCs and
Remote I/Os)
Non-Safe
Communication
available with
references:
XPSMF3022, and
XPSMF31222
Connections:
page 2/32
OFF 2
Screw
31
32
33
34
35
36
37
38
39
40
41
42
Type
SUB-D 9-pin
(FB3)
Integrated 4
RJ45 switched
Ethernet
Communication
ports
Screw Function
LS+
13
14
15
16
L-
LS+
17
18
19
20
L-
Sensor supply for inputs 13 to 16
Digital input 13
Digital input 14
Digital input 15
Digital input 16
Inputs common
Sensor supply for inputs 17 to 20
Digital input 17
Digital input 18
Digital input 19
Digital input 20
Inputs common
Function
XPSMF3022: slave on Modbus® serial
(RTU)
Either of the four switched Ethernet
ports can be used to create a
connection between the safety PLC
and the programming terminal in a
point to point or via an Ethernet
network for programming, setting IP
address etc.
Either of the four switched Ethernet
ports can be used to create a
connection between the safety PLC
and other safety related components
(e.g other XPSMF safety PLCs or
Safety Remote I/O modules) this can
be established in a point to point way or
via an Ethernet network.
Either of the four switched Ethernet
ports can be used to create a
connection between the safety PLC
and other non- safety related
components (e.g HMI Magelis ®,
standard PLCs, Scada systems,etc.)
this can be established in a point to
point way or via an Ethernet network.
Presentation:
page 2/18