XPSAF5130P SQUARE D, XPSAF5130P Datasheet - Page 24

SAFETY RELAY 300V 2.5A PREVENTA

XPSAF5130P

Manufacturer Part Number
XPSAF5130P
Description
SAFETY RELAY 300V 2.5A PREVENTA
Manufacturer
SQUARE D
Datasheet

Specifications of XPSAF5130P

Contact Current Max
30mA
Contact Voltage Dc Nom
24V
Contact Configuration
3NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
22.5mm
Rohs Compliant
Yes
Description (continued)
Safety automation system solutions
Preventa™ safety PLCs
Compact, XPSMF31/30/35
FB1, FB2
FB3
Inputs 1 to 20 Orange
Outputs
1 to 8
24 VDC
RUN
ERROR
PROG
FORCE
FAULT
OSL
BL
RJ45
(1) Depending on PLC model.
Status LED details
Compact safety PLCs XPSMF31222, XPSMF3022 and XPSMF35pp
LED
Green
Green
Red
Orange
Orange
Orange
Orange
Orange
Green
Yellow
Color
Orange
Orange
Status
On
On
On
On
Off
On
Flashing
Off
On
Off
On
Flashing
Off
On
Flashing
Off
On
Flashing
Off
Flashing
Flashing
On
Flashing
Off
On
Flashing
Meaning
Not used.
Communication on Modbus® serial or PROFIBUS DP
(1) active.
Inputs active.
Outputs active.
c 24 V voltage present.
No voltage.
Normal service mode, loaded program running, the
PLC receives I/O messages, communication and
hardware/software tests carried out.
The CPU is in STOP and is not executing any user
application.
All the outputs are reset to a safe, de-energized state.
The CPU is in “ERROR” state (see ERROR).
Software error or hardware anomaly detected by the
CPU.
The monitoring program (Watchdog) has triggered the
STOP state of the process because the programmed
cycle time has been exceeded.
The CPU has stopped the execution of the user
application, ended all hardware and software tests and
all outputs have been reset.
The process can only be started again from the PC.
No errors detected.
The CPU is being loaded with a new configuration.
The FLASH ROM is being loaded with a new operating
system.
No loading of configuration or operating system.
The CPU is in RUN mode and force is active.
The system is not processing (STOP), but force is
prepared and is activated if the dual processor is
started.
Force mode not activated.
Error display for line control.
The user application has caused an error.
The system configuration is defective.
The loading of a new operating system was defective
and the operating system is corrupt.
An error has occurred while writing to FLASH ROM
memory (during updating of the operating system).
One or more I/O errors have occurred.
None of the above errors have occurred.
Emergency loading of the operating system is active.
COM in INIT_Fail state.
Full duplex mode operation.
Signal collision.
Half duplex mode operation, no collision.
Connection established.
Interface active.
2/23
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9

Related parts for XPSAF5130P