XC5VLX50T-2FFG665I Xilinx Inc, XC5VLX50T-2FFG665I Datasheet - Page 108

IC FPGA VIRTEX-5 50K 665FCBGA

XC5VLX50T-2FFG665I

Manufacturer Part Number
XC5VLX50T-2FFG665I
Description
IC FPGA VIRTEX-5 50K 665FCBGA
Manufacturer
Xilinx Inc
Series
Virtex™-5 LXTr

Specifications of XC5VLX50T-2FFG665I

Number Of Logic Elements/cells
46080
Number Of Labs/clbs
3600
Total Ram Bits
2211840
Number Of I /o
360
Voltage - Supply
0.95 V ~ 1.05 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
665-BBGA, FCBGA
For Use With
HW-V5-ML561-UNI-G - EVALUATION PLATFORM VIRTEX-5HW-V5-ML550-UNI-G - EVALUATION PLATFORM VIRTEX-5HW-V5-ML521-UNI-G - EVALUATION PLATFORM VIRTEX-5HW-V5GBE-DK-UNI-G - KIT DEV V5 LXT GIGABIT ETHERNET122-1508 - EVALUATION PLATFORM VIRTEX-5
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XC5VLX50T-2FFG665I
Manufacturer:
Xilinx Inc
Quantity:
10 000
Part Number:
XC5VLX50T-2FFG665I
Manufacturer:
XILINX
0
Part Number:
XC5VLX50T-2FFG665I
Quantity:
2 392
Part Number:
XC5VLX50T-2FFG665I
0
Chapter 3: Phase-Locked Loops (PLLs)
X-Ref Target - Figure 3-14
108
1
Matches
IBUFG
PLL Driving DCM
2
3
CLKIN1
CLKFBIN
RST
CLKIN
CLKFBIN
RST
A second option for reduce clock jitter is to use the PLL to clean-up the input clock jitter
before driving into the DCM. This will improve the output jitter of all DCM outputs, but
any added jitter by the DCM will still be passed to the clock outputs. Both PLL and DCM
should reside in the same CMT block because dedicated resources exist between the PLL
and DCM to support the zero delay mode. When the PLL and DCM do not reside in the
same CMT, then the only connection is through a BUFG hindering the possibility of
deskew.
One PLL can drive multiple DCMs as long as the reference frequency can be generated by
a single PLL. For example, if a 33 MHz reference clock is driven into the PLL, and the
design uses one DCM to operate at 200 MHz and the other to run at 100 MHz, then the
VCO can be operated at 600 MHz (M1 = 18). The VCO frequency can be divided by three to
generate a 200 MHz clock and another counter can be divided by six to generate the
100 MHz clock. For the example in
DCM
PLL
CLKFBOUT
CLKFX180
CLK2X190
CLKOUT0
CLKOUT1
CLKOUT2
CLKOUT3
CLKOUT4
CLKOUT5
CLK190
CLK270
CLKDV
CLKFX
CLK2X
CLK90
CLK0
Figure 3-14: PLL Driving a DCM
www.xilinx.com
BUFG
Figure
4
5
6
3-14, one PLL can drive both DCMs.
To Logic, etc.
To Logic, etc.
1
2
3
4
5
6
Virtex-5 FPGA User Guide
UG190 (v5.3) May 17, 2010
ug190_3_14_092107

Related parts for XC5VLX50T-2FFG665I