SAM3A4C Atmel Corporation, SAM3A4C Datasheet - Page 701

no-image

SAM3A4C

Manufacturer Part Number
SAM3A4C
Description
Manufacturer
Atmel Corporation
Datasheets
32.8.5
Name:
Address:
Access:
• RDRF: Receive Data Register Full
0 = No data has been received since the last read of SPI_RDR
1 = Data has been received and the received data has been transferred from the serializer to SPI_RDR since the last read
of SPI_RDR.
• TDRE: Transmit Data Register Empty
0 = Data has been written to SPI_TDR and not yet transferred to the serializer.
1 = The last data written in the Transmit Data Register has been transferred to the serializer.
TDRE equals zero when the SPI is disabled or at reset. The SPI enable command sets this bit to one.
• MODF: Mode Fault Error
0 = No Mode Fault has been detected since the last read of SPI_SR.
1 = A Mode Fault occurred since the last read of the SPI_SR.
• OVRES: Overrun Error Status
0 = No overrun has been detected since the last read of SPI_SR.
1 = An overrun has occurred since the last read of SPI_SR.
An overrun occurs when SPI_RDR is loaded at least twice from the serializer since the last read of the SPI_RDR.
• NSSR: NSS Rising
0 = No rising edge detected on NSS pin since last read.
1 = A rising edge occurred on NSS pin since last read.
• TXEMPTY: Transmission Registers Empty
0 = As soon as data is written in SPI_TDR.
1 = SPI_TDR and internal shifter are empty. If a transfer delay has been defined, TXEMPTY is set after the completion of
such delay.
• UNDES: Underrun Error Status (Slave Mode Only)
0 = No underrun has been detected since the last read of SPI_SR.
11057A–ATARM–17-Feb-12
11057A–ATARM–17-Feb-12
31
23
15
7
SPI Status Register
30
22
14
SPI_SR
0x40008010 (0), 0x4000C010 (1)
Read-only
6
29
21
13
5
28
20
12
4
OVRES
27
19
11
3
UNDES
MODF
26
18
10
2
TXEMPTY
TDRE
25
17
9
1
SAM3X/A
SAM3X/A
SPIENS
NSSR
RDRF
24
16
8
0
701
701