at91sam9263 ATMEL Corporation, at91sam9263 Datasheet - Page 745

no-image

at91sam9263

Manufacturer Part Number
at91sam9263
Description
At91 Arm Thumb Microcontrollers
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM9263
Manufacturer:
AT
Quantity:
1
Part Number:
at91sam9263-CJ
Manufacturer:
ATMEL
Quantity:
181
Part Number:
at91sam9263-CU
Manufacturer:
ATMEL
Quantity:
132
Part Number:
at91sam9263-EK
Manufacturer:
Atmel
Quantity:
135
Part Number:
at91sam9263B-CU
Manufacturer:
IDT
Quantity:
1 043
Part Number:
at91sam9263B-CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at91sam9263B-CU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at91sam9263B-CU-100
Manufacturer:
ATMEL
Quantity:
1 000
Part Number:
at91sam9263B-CU-100
Manufacturer:
ATMEL
Quantity:
3 060
Part Number:
at91sam9263B-CU-100
Manufacturer:
Atmel
Quantity:
10 000
Figure 39-9. Command/Response Functional Flow Diagram
Note:
39.7.2
6249D–ATARM–20-Dec-07
1. If the command is SEND_OP_COND, the CRC error flag is always present (refer to R3 response in the MultiMedia Card
Data Transfer Operation
specification).
Check error bits in the
The MultiMedia Card allows several read/write operations (single block, multiple blocks, stream,
etc.). These kind of transfers can be selected setting the Transfer Type (TRTYP) field in the MCI
Command Register (MCI_CMDR).
These operations can be done using the features of the Peripheral DMA Controller (PDC). If the
PDCMODE bit is set in MCI_MR, then all reads and writes use the PDC facilities.
In all cases, the block length (BLKLEN field) must be defined either in the mode register
MCI_MR, or in the Block Register MCI_BLKR. This field determines the size of the data block.
Enabling PDC Force Byte Transfer (PDCFBYTE bit in the MCI_MR) allows the PDC to manage
with internal byte transfers, so that transfer of blocks with a size different from modulo 4 can be
supported. When PDC Force Byte Transfer is disabled, the PDC type of transfers are in words,
otherwise the type of transfers are in bytes.
Wait for command
status register
ready status flag
(1)
Set the command argument
MCI_ARGR = Argument
Read response if required
MCI_CMDR = Command
Status error flags?
Set the command
Read MCI_SR
RETURN OK
CMDRDY
1
(1)
AT91SAM9263 Preliminary
RETURN ERROR
Yes
0
(1)
745

Related parts for at91sam9263