at91sam9263 ATMEL Corporation, at91sam9263 Datasheet - Page 765

no-image

at91sam9263

Manufacturer Part Number
at91sam9263
Description
At91 Arm Thumb Microcontrollers
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM9263
Manufacturer:
AT
Quantity:
1
Part Number:
at91sam9263-CJ
Manufacturer:
ATMEL
Quantity:
181
Part Number:
at91sam9263-CU
Manufacturer:
ATMEL
Quantity:
132
Part Number:
at91sam9263-EK
Manufacturer:
Atmel
Quantity:
135
Part Number:
at91sam9263B-CU
Manufacturer:
IDT
Quantity:
1 043
Part Number:
at91sam9263B-CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at91sam9263B-CU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at91sam9263B-CU-100
Manufacturer:
ATMEL
Quantity:
1 000
Part Number:
at91sam9263B-CU-100
Manufacturer:
ATMEL
Quantity:
3 060
Part Number:
at91sam9263B-CU-100
Manufacturer:
Atmel
Quantity:
10 000
The NOTBUSY flag allows to deal with these different states.
0 = The MCI is not ready for new data transfer. Cleared at the end of the card response.
1 = The MCI is ready for new data transfer. Set when the busy state on the data line has ended. This corresponds to a free
internal data receive buffer of the card.
Refer to the MMC or SD Specification for more details concerning the busy behavior.
• ENDRX: End of RX Buffer
0 = The Receive Counter Register has not reached 0 since the last write in MCI_RCR or MCI_RNCR.
1 = The Receive Counter Register has reached 0 since the last write in MCI_RCR or MCI_RNCR.
• ENDTX: End of TX Buffer
0 = The Transmit Counter Register has not reached 0 since the last write in MCI_TCR or MCI_TNCR.
1 = The Transmit Counter Register has reached 0 since the last write in MCI_TCR or MCI_TNCR.
Note:
• RXBUFF: RX Buffer Full
0 = MCI_RCR or MCI_RNCR has a value other than 0.
1 = Both MCI_RCR and MCI_RNCR have a value of 0.
• TXBUFE: TX Buffer Empty
0 = MCI_TCR or MCI_TNCR has a value other than 0.
1 = Both MCI_TCR and MCI_TNCR have a value of 0.
Note:
• RINDE: Response Index Error
0 = No error.
1 = A mismatch is detected between the command index sent and the response index received. Cleared when writing in
the MCI_CMDR.
• RDIRE: Response Direction Error
0 = No error.
1 = The direction bit from card to host in the response has not been detected.
• RCRCE: Response CRC Error
0 = No error.
1 = A CRC7 error has been detected in the response. Cleared when writing in the MCI_CMDR.
• RENDE: Response End Bit Error
0 = No error.
1 = The end bit of the response has not been detected. Cleared when writing in the MCI_CMDR.
6249D–ATARM–20-Dec-07
BLKE and NOTBUSY flags can be used to check that the data has been successfully transmitted on the data lines and not only
transferred from the PDC to the MCI Controller.
BLKE and NOTBUSY flags can be used to check that the data has been successfully transmitted on the data lines and not only
transferred from the PDC to the MCI Controller.